4 - 1
4-1 PREPARATION
‘
‘
REQUIRED TEST EQUIPMENT
■
CONNECTION
EQUIPMENT
Exciter (Transceiver)
RF power meter
(terminated type)
GRADE AND RANGE
Frequency range
: 1.8–60 MHz
Output power
: 50–100 W
Mode
: RTTY or FM
IC-736 (for tuner basis voltage adjustment)
Measuring range
: 10–1500 W
Frequency range
: 1.8–60 MHz
Impedance
: 50
Ω
SWR
: Less than 1.2 : 1
EQUIPMENT
Ammeter
RF dummy load
Digital DC voltmeter
DC voltmeter
Load-resistor
GRADE AND RANGE
Capability
: 0.1–100 A
Impedance
: 50, 100 and 150
Ω
Capability
: 1500 W or more
Input impedance
: 10 M
Ω
/V DC or better
Input impedance
: 50 k
Ω
/V DC or better
Capability
: 9.7–10.3 A
SECTION 4
ADJUSTMENT PROCEDURES
IC-PW1
EXCITER
Ground
Coaxial cable
Coaxial cable
to the ANT1 connector
RF power meter
1500 W/50
Ω
RF
dummy load
INPUT1
GND
GND
RF OUT
AC outlet
[USA]
: 100–120/220–240 V
[EUR] and [EUR-1] : 230 V
Connect 2-conductor plug to REMOTE
connector when adjusting meter maximum
point.
1/8" (3.5 mm)
2-conductor plug
Shorten inner and outer plugs
Summary of Contents for IC-PW1
Page 1: ...SERVICE MANUAL ADDENDUM CONTENTS PARTS LIST 1 BOARD LAYOUTS 16 Jun 2010 ...
Page 19: ...SERVICE MANUAL ADDENDUM CONTENTS PARTS LIST 1 BOARD LAYOUTS 16 VOLTAGE DIAGRAM 18 Apr 2010 ...
Page 152: ...MNF F1 EP2 TO REGRELAY BOARD MLF EP1 F2 TO REGRELAY BOARD EP35 I N FG 8 19 FIL AC BOARD 8 20 ...