background image

13

3

OPERATION

CAUTION:

DO NOT operate the IC-PW1 before adjusting the
ALC levels properly with the [ALC adj1] and 
[ALC adj2] pots. (p. 11)

It takes 15 sec. for CI-V line initial settings when
several CI-V devices (more than 5) are connected
to a CI-V line.

For IC-781 users with other Icom CI-V transceivers:

Turn the IC-781 power ON before turning the
IC-PW1 and other transceiver power ON and keep
the IC-781 power ON during operation.

q

Push [POWER] to turn the linear amplifier ON then
turn the exciter’s power ON.

w

Select the input/output antenna with [INPUT] and
[ANT].

e

Set the exciter to CW or RTTY mode with minimum
output power.

r

Select the temperature and SWR meters with
[METER-1] and [METER-2].

- The [TEMP] and [SWR] indicators light.

t

Push [TUNER] and [AMP/PROTECT] to turn the
automatic antenna tuner and linear amplifier circuit
ON.

y

Push [UP]/[DOWN] to select [AUTO] for automatic
band selection when a CI-V Icom exciter is used;
or push [UP]/[DOWN] to select the desired band
for manual band selection.

u

Use the exciter’s antenna tuner to tune the line be-
tween the IC-PW1 and exciter, if you have an an-
tenna tuner connected to the exciter.

i

Transmit with the exciter and adjust the exciter’s
output power to 50 W with the RF output power
control on the exciter.

- [TRANSMIT] indicator lights.
- See the exciter’s instruction manual for transmitting.

o

The built-in antenna tuner automatically tunes the
antenna.

- SWR reading on meter-2 should be less than 1.2:1.
- Push [TUNER] for 2 sec. to tune the antenna manually.
- The [TUNER] indicator blinks while tuning.
- The [TUNER] indicator lights while the tuner is acti-

vated.

NOTE: The band information is not updated while
scanning. Turn the antenna tuner OFF and use the
manual band selection while scanning.

During split operation:

When changing the frequency more than 100 kHz,
the IC-PW1’s antenna tuner presets the tuner to
the new frequency. Use manual tuning during split
operation.

!0

When operating for long periods, select the tem-
perature meter with [METER-1] to monitor the lin-
ear amplifier’s temperature.

- If the temperature meter reading is in the red “HOT”

zone, the exciter should be returned to receive, other-
wise, the protection circuit may be activated and the lin-
ear amplifier may be turned OFF.

D

Band memory

The IC-PW1 stores ON/OFF settings for the antenna
tuner and linear amplifier according to the operating
band when at least 1 Icom exciter is connected to the
[INPUT1] connector.

The set conditions may not be stored when the lin-
ear amplifier is turned OFF immediately after set-
ting the antenna tuner and linear amplifier.

Operation

HF/50MHz ALL BAND 1kW LINEAR AMPLIFIER

iPW1

POWER

TRANSMIT

TUNER

DOWN

UP

AUTO

AMP/
PROTECT

1.8

3.5

7

10

14

18

21

24

28

50

TEMP

I

D

Po

ALC

SWR

V

D

METER-1

METER-2

ANT

INPUT

z
x

z
x

c
v

[POWER]

HF/50MHz ALL BAND 1kW LINEAR AMPLIFIER

iPW1

POWER

TRANSMIT

TUNER

DOWN

UP

AUTO

AMP/
PROTECT

1.8

3.5

7

10

14

18

21

24

28

50

TEMP

I

D

Po

ALC

SWR

V

D

METER-1

METER-2

ANT

INPUT

z
x

z
x

c
v

HF/50MHz ALL BAND 1kW LINEAR AMPLIFIER

iPW1

POWER

TRANSMIT

TUNER

DOWN

UP

AUTO

AMP/
PROTECT

1.8

3.5

7

10

14

18

21

24

28

50

TEMP

I

D

Po

ALC

SWR

V

D

METER-1

METER-2

ANT

INPUT

z
x

z
x

c
v

[TUNER]

[AMP/PROTECT]

METER-1

Temperature
protection range

Summary of Contents for IC-PW1

Page 1: ...INSTRUCTION MANUAL iPW1 HF 50 MHz ALL BAND 1 kW LINEAR AMPLIFIER...

Page 2: ...lifier AVOID using or placing the linear amplifier or remote controller in areas with temperatures below 10 C 14 F or above 40 C 104 F AVOID placing the linear amplifier or remote controller in excess...

Page 3: ...tenna tuner operation 14 Protection circuit 14 4 MAINTENANCE 15 Troubleshooting 15 5 SPECIFICATIONS 16 EXPLICIT DEFINITIONS UNPACKING TABLE OF CONTENTS ii q w e r t y i o 0 u Accessories included with...

Page 4: ...24 28 50 UP ANT INPUT AUTO TRANSMIT TUNER AMP PROTECT POWER V 1 2 1 2 3 4 HF 50MHz ALL BAND 1kW LINEAR AMPLIFIER w r e t q y u i o 0 3 4 5 1 2 0 100 250 500 1K 1 5K 0 TEMP ALC ALC adj SWR 0 1 1 5 2 3...

Page 5: ...ier ON and OFF The AMP PROTECT indicator lights green when the linear amplifier is ON p 13 The AMP PROTECT indicator lights red when the pro tector circuit is activated p 14 When the linear amplifier...

Page 6: ...D CONTROL JACKS SEND1 SEND2 pgs 8 9 Input terminals for transmit control Go to ground while transmitting Max control level 5 0 V DC 0 1 A Ground level 0 5 to 0 8 V DC y CI V REMOTE CONTROL JACKS REMOT...

Page 7: ...NO PIN NAME DESCRIPTION SPECIFICATIONS 1 8 V Regulated reference 8 V DC output from the ACC 1 socket Output voltage 8 V 0 3 V Output current Less than 10 mA 2 GND Connects to ground 3 SEND Input outp...

Page 8: ...G should be attached to the AC cable of the IC PW1 as illustrated below This will help prevent interference such as TVI etc OPC 853 AC cable with line filter The IC PW1 Europe version must be used wit...

Page 9: ...ne should be a coaxial cable When using 1 antenna use the ANT1 connector CAUTION Protect your linear amplifier from light ning by using a lightning arrestor 6 2 INSTALLATION AND CONNECTIONS PL 259 CON...

Page 10: ...ble supplied ACC cable supplied Remote control cable supplied To an antenna ANT ACC 1 ANT1 REMOTE REMOTE INPUT1 GND GND IC 706 series ACC 13 pins OPC 599 optional EXCITER 1 1 2 AC outlet Non Europe ve...

Page 11: ...ries OPK 5 optional OPK 5 optional Be sure to connect the cable to the 7 pin ACC 2 jack AC outlet Non Europe versions 100 120 220 240 V Europe version 230 V Using a non Icom exciter transceiver Set th...

Page 12: ...tions even when the IC PW1 power is OFF In addition set the jumper on the IC PW1 controller to 2 to turn the controller s LEDs OFF as shown at right When the jumper is set to 2 the CI V control does n...

Page 13: ...he control cable with the supplied sepa ration cable through the cable hole Use the shorter end from the bushing to connect to the remote controller u Remove 2 screws from the cable hole cover on the...

Page 14: ...he exciter q Select an antenna which has an SWR of 1 5 1 or better w Set the 1st exciter s RF output power for the mini mum output e Be sure that the ALC adj1 and ALC adj2 pots on the rear panel max c...

Page 15: ...ically selected using the exciter s baud rate DWhen using 1 Icom exciter q While pushing INPUT push POWER to enter the CI V address programming mode INPUTz blinks w Rotate the Icom exciter s tuning di...

Page 16: ...lly The TUNER indicator blinks while tuning The TUNER indicator lights while the tuner is acti vated NOTE The band information is not updated while scanning Turn the antenna tuner OFF and use the manu...

Page 17: ...to cancel the protection circuit The built in automatic antenna tuner can match the antenna feed line impedance to 50 when the feed line impedance is within 16 7 to 150 for HF bands VSWR 3 1 or withi...

Page 18: ...r ON The indicator lights green Select an antenna suitable for the operating frequency Push TUNER for 2 sec to manually tune the antenna Stop the exciter s transmission then push AMP PROTECT to deacti...

Page 19: ...1 80 1 95 MHz of the 1 8 MHz band Minimum operating 60 W input power Tuning accuracy VSWR 1 5 1 or less Insertion loss Less than 1 0 dB after tuning MODE INPUT AC VOLTAGE 200 240 V AC 100 120 V AC CW...

Page 20: ...6 9 16 Kamihigashi Hirano ku Osaka 547 0002 Japan A 5449G 1EX w Printed in Japan 1997 Icom Inc Count on us...

Reviews: