![Icom IC-M1EURO V Service Manual Download Page 14](http://html.mh-extra.com/html/icom/ic-m1euro-v/ic-m1euro-v_service-manual_612736014.webp)
5 - 3
1
2
1
1
2
3
1
• Operating channel : ch 16
• Receiving
• Operating channel : ch 16
• Connect the RF power meter or 50
Ω
dummy load to the antenna connector.
• Transmitting
• Operating channel : ch 16
• Connect the RF power meter or 50
Ω
dummy load to the antenna connector.
• Transmitting
• Operating channel : ch 16
• [H/L] switch
: High
• Transmitting
• [H/L] switch
: Low
• Transmitting
• [H/L] switch
: Extra low
• Transmitting
• Operating channel : ch 16
• [H/L] switch
: High
• Connect the audio generator to the
[MIC] jack and set as:
1.0 kHz/40 mV rms.
• Set the FM deviation meter as:
HPF
: OFF
LPF
: 20 kHz
De-emphasis
: OFF
Detector
: (P–P)/2
• Transmitting
PLL
LOCK
VOLTAGE
REFERENCE
FREQUENCY
OUTPUT
POWER
FM
DEVIATION
Top
panel
Top
panel
Top
panel
Use the adjustment program.
(see page 5-2)
Loosely couple the frequnecy
counter to the antenna connec-
tor.
Connect the RF power meter to
the antenna connector.
Connect the FM deviation meter
to the antenna connector
through the attenuator.
2.3–3.3 V
Verify on the com-
puter display (LVIN)
156.800000 MHz
5.0 W (except [FRG])
1.0 W ([FRG] only)
1.0 W (except [FRG])
0.5 W ([FRG] only)
0.5 W (except [FRG])
±4.3 kHz
ADJUSTMENT
ADJUSTMENT CONDITION
MEASUREMENT
VALUE
UNIT
LOCATION
5-2 PLL AND TRANSMITTER ADJUSTMENTS
Select an operation using [
↑
] / [
↓
] keys, then set specified value using [
←
] / [
→
] keys on the connected computer keyboard.