July 2016
(Amended page)
6-7 RECEIVE ADJUSTMENT
(For [#07], [#14], [#15], [#16], [#23], [#35], [#36], [#37] and [#82])
1) Select an adjustment item using cursor or [
] / [
] keys of the PC’s keyboard.
2) Set or modify the adjustment value as specifi ed using [
] / [
] keys of the PC’s keyboard, then push the [ENTER] key.
ADJUSTMENT
ADJUSTMENT CONDI-
TION
OPERATION
ADJUST-
MENT
ITEM/
POINT
VALUE
RECEIVE
SENSITIVITY
1 • Channel: 1-27
• Receiving
1) Connect the SSG to the RX antenna
connector, and set to:
Level
†
:
+20 dBµ (–87 dBm)
Modulation: 1
kHz
Deviation: ±3.5
kHz
Frequency: 136.100
MHz
2) Select the item
[BPF C ALL]
, then
push the [ENTER] key.
[BPF C
ALL]
(Automatic
adjustment)
S-METER
(S3 level)
NOTE:
"RECEIVE SENSITIVITY" MUST be adjusted before "S-METER." When "RECEIVE SENSITIVITY" is re-
adjusted, "S-METER" MUST be re-adjusted, too.
1 • Channel: 1-28
• Receiving
1) Set the SSG set to:
Frequency: 173.900
MHz
Modulation: 1
kHz
Deviation: ±3.5
kHz
Level
†
:
+23 dBµ (–84 dBm)
2) Select the item
[RSSI S3 Level]
,
then push the [ENTER] key to store
the adjust value.
[RSSI S3
Level]
(Automatic
adjustment)
(S1 level)
2 • Channel: 1-28
• Receiving
1) Set the SSG set to:
Level
†
:
–7 dBµ (–114 dBm)
2) Select the item
[RSSI S1 Level]
,
then push the [ENTER] key, to store
the adjust value.
[RSSI S1
Level]
(Automatic
adjustment)
SQUELCH
-Preparation-
1
–
• Set the item
[SQL Level]
to "2."
[SQL Level]
"2"
2 • Connect the SSG to the RX
antenna connector.
• Set the SSG set to:
Frequency: 136.100
MHz
Modulation: 1
kHz
Deviation: ±3.5
kHz
Level
†
:
–13 dBµ (–120 dBm)
–
–
-Adjust-
3 • Channel: 1-29
• Receiving
• Push
[ENTER]
key to store the value.
[SQL]
To the level where
the squelch just
opens.
†
; The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.
6-11