5 - 5
5-3 PA AND FILTER UNITS ADJUSTMENT
IDLING
CURRENT
(For drive
FETs)
(For final
transistors)
SWR
DETECTOR
1
2
• Operating frequency : 12.2350 MHz
• Mode
: J3E
• Apply no audio signal to the [MIC] con-
nector.
• Disconnect J6702.
• Preset R6304 and R6412 on the PA
unit to max. counter clockwise.
• Preset R6515 on the PA unit to max.
clockwise.
• Connect a dummy load or RF power
meter to the [ANT] connector.
• Transmitting
• Transmitting
• Operating frequency : 22.0000 MHz
• Mode
: J3E
• Connect the CP7332 (FOR line) on
the FILTER unit to ground.
• Connect an audio generator to the
[MIC] connector and set as:
Frequency
: 1.5 kHz
Level
: OFF
• Transmitting
Rear
panel
Rear
panel
FIL-
TER
Connect an ammeter
(10 A) between an
external power supply
and the transceiver.
Connect an RF power
meter to the [ANT]
connector.
Connect a DC volt-
meter to the check
point, CP7331.
2.0 A
0.7 A
90 W
Minimum level
PA
Audio
gen-
erator
FIL-
TER
R6304
R6412
Output
level
C7275
ADJUSTMENT
ADJUSTMENT CONDITIONS
UNIT
LOCATION
VALUE
UNIT
ADJUST
MEASUREMENT
ADJUSTMENT
• After adjustment, connect J6701 to the PA unit.
1
2
• After adjustment, disconnect CP7332 (FOR line) on the FILTER unit from ground.
Summary of Contents for IC-F7000
Page 1: ...HF TRANSCEIVER iF7000 SERVICE MANUAL ...
Page 61: ... BOTTOM VIEW MAIN UNIT 9 8 ...
Page 63: ... BOTTOM VIEW PA UNIT 9 10 ...
Page 65: ...1 4 8 1 4 8 5 5 9 12 BOTTOM VIEW PLL UNIT ...
Page 66: ...9 3 5 DRIVER BOARD TOP VIEW 9 13 GND VARO VARI to PA unit J6411 9 3 6 VARISTOR 1 BOARD ...
Page 78: ......
Page 79: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan S 14012HZ C1 C 2003 Icom Inc ...