![Icom IC-F4261DS Service Manual Download Page 58](http://html.mh-extra.com/html/icom/ic-f4261ds/ic-f4261ds_service-manual_612583058.webp)
5 - 5
FREQUENCY ADJUSTMENTS
1) Select an adjustment item using [
↑
]/[
↓
] on the PC's keyboard.
2) Set or modify the adjustment value as specifi ed using [
←
]/[
→
] on the PC's keyboard, and then push [ENTER].
(The values shown above are exsample only.
Each transceiver has own values.)
Lock voltage will be displayed here.
• I/O Check window
ADJUSTMENT
TRANSCEIVER’S
CONDITION
OPERATION
ADJUSTMENT
ITEM
VALUE
PLL LOCK
VOLTAGE
1
–
1) Connect an RF power meter to the an-
tenna connector.
2) Set the preset adjustment value on the
adjustment utility window.
[LV (RX 1)]
[LV (RX 2)]
[LV (TX)]
"51"
(for each)
(RX band low)
2
• Channel
: 1-1
• Receiving
• Select the item
[RX LVA1]
, and then push
[ENTER]
.
[RX LVA1]
1.00 V
(RX band center)
3
• Channel
: 1-2
• Receiving
• Select the item
[RX LVA2]
, and then push
[ENTER]
.
[RX LVA2]
(TX)
4
• Channel
: 1-3
• Transmitting
• Select the item
[TX LVA]
, and then push
[ENTER]
.
[TX LVA]
(RX band center)
5
• Channel
: 1-4
• Receiving
• Click the
[Reload (F5)]
button to check on
the "I/O Check window" as below.
[LVIN]
(On the "I/O
Check window")
3.2–4.4 V*
3.4–4.4 V**
3.5–4.5 V***
(Verify)
(RX band high)
6
• Channel
: 1-5
• Receiving
3.2–4.4 V*
3.4–4.4 V**
3.5–4.5 V***
(Verify)
(TX)
7
• Channel
: 1-6
• Transmitting
3.2–4.4 V*
2.5–3.5 V**
3.2–4.4 V***
(Verify)
REFERENCE
FREQUENCY
1
• Channel
: 1-7
• Transmitting
• Loosely couple a frequency counter to the
antenna connector.
[REF]
470.000000
MHz*
520.000000
MHz**
400.000000
MHz***
(±50 Hz)
*; [Low band] **; [High band] ***; [350 MHz band]