FUNCTION DISPLAY
D
Turning ON the transceiver
NOTE:
Before using the transceiver for the first time, the
battery pack must be fully charged for optimum life and
operation. See the BATTERY CHARGING section of this
sheet.
1. Rotate [VOL] to turn ON the transceiver.
2. If the transceiver is preset for a start up password,
enter the digit codes as directed by your dealer.
• The 10-keypad may be used for password input,
depending on the transceiver’s version.
• The keys in the table below can be used for password
input.
• The transceiver detects numbers in the same block
as identical. Therefore “01234” and “56789” are the
same.
KEY
NUMBER
0
5
4
9
3
8
2
7
1
6
[Side3]
[P0]/[P1]/
[P2]/[P3]
Side3
[VOL]
3.
When the “PASSWORD” indication does not clear after
entering 4 digits, the entered code number may be
incorrect. Restart the transceiver in this case.
D
Receiving and Transmitting
Receiving:
1. Push [CH Up] or [CH Down] to sequentially select the
conventional system channel.
2. When receiving a call, adjust the audio output level to
a comfortable listening level.
Transmitting:
CAUTION:
Attach an antenna before transmitting.
Transmitting without an antenna may damage the
transceiver.
1. Wait until the channel is clear to avoid interference.
2. While holding down [PTT], speak at your normal voice
level.
3. Release [PTT] to receive.
IMPORTANT:
To maximize the readability of your signal:
1. After pushing [PTT], pause briefly before you start
speaking.
2. Hold the microphone 5 to 10 cm (2 to 4 inches) from
your mouth, then speak at your normal voice level.
BASIC OPERATION
BATTERY CHARGING
D
Rapid charging with the BC-160
The optional BC-160 rapidly charges the Li-ion battery
pack.
• A power adapter (may be supplied with BC-160,
depending on the version) or the DC power cable (OPC-
515L/CP-23L) is additionally required.
CAUTION:
NEVER reverse the polarity when connecting
the OPC-515L to a power source. This will ruin the battery
charger.
White line:
+
, Black line:
_
D
AD-106 installation
The AD-106
CHARGER ADAPTER
must be installed into
the BC-119N or BC-121N before battery charging.
1. Connect the AD-106 and the BC-119N or BC-121N.
2. Install the AD-106 into the holder space of the BC-
119N or BC-121N with the supplied screws.
Battery
Pack
Battery Pack
+ Transceiver
Turn OFF
Power Adapter*
The
OPC-515L
(for a 13.8 V DC
power source)
or the CP-23L
(for a 12 V
cigarette lighter
socket) can be
used instead
of the power
adapter.
* A different type, or no power adapter is supplied,
depending on the charger version.
OPTIONS
D
BATTERY PACK/BATTERY CASE
Battery
pack
Voltage
Capacity
Battery life*
BP-232WP
7.4 V 2250 mAh (min.)
2300 mAh (typ.)
VHF
19 hrs.
UHF
17 hrs.
* When the power save function is turned ON, and the
operating periods are calculated under the following
ratio:
TX : RX : standby = 5 : 5 : 90
•
BP-240/BP-261
BATTERY CASE
BP-240: Battery case for 6 AAA (LR03) alkaline batteries
BP-261: Battery case for 6 AA (LR6) alkaline batteries
BP-240 and BP-261 have IPX4 waterproof protection.
When in use, the transceiver’s waterproof rating meets
IPX4. Operating period depends on the alkaline cells used.
D
CHARGERS
•
BC-119N
DESKTOP CHARGER
+
AD-106
CHARGER
A
BC-145S
AC ADAPTER
To rapidly charge the battery pack. A power adapter may
supplied with the charger, depending on the versions.
Charging time: Approximately 3.5 hours for the BP-232WP.
•
BC-121N
MULTI-CHARGER
+
AD-106
CHARGER
ADAPTER (6 pcs.) +
BC-157S
AC ADAPTER
For rapidly charging of up to 6 battery packs
simultaneously. A power adapter should be purchased
separately.
Charging time: Approximately 3.5 hours for the BP-232WP.
•
BC-160
DESKTOP CHARGER
+
BC-123S
AC ADAPTER
To rapidly charge the battery pack. A power adapter may
be supplied with the charger, depending on the versions.
Charging time: Approximately 3.5 hours for the BP-232WP.
•
BC-171
DESKTOP CHARGER
+
BC-147S
AC ADAPTER
A power adapter may supplied with the charger, depending
on the versions.
Charging time: Approximately 11.5 hours for the BP-232WP.
•
BC-197
MULTI-CHARGER
For rapidly charging of up to 6 battery packs
simultaneously. A power adapter may be supplied with the
charger, depending on the version.
Charging time: Approximately 3.5 hours for the BP-232WP.
D
DC CABLES
•
CP-23L
CIGARETTE LIGHTER CABLE
Used when charging a battery pack through a 12 V
cigarette lighter socket. (For BC-160/BC-171/BC-119N)
•
OPC-515L/OPC-656
DC POWER CABLES
Used when charging a battery pack through a 13.8 V
power source instead of the power adapter.
OPC-515L: For BC-119N/BC-160/BC-171
OPC-656: For BC-121N/BC-197
D
BELT CLIPS
•
MB-93
SWIVEL BELT CLIP
•
MB-94/MB-94R
BELT CLIP
Exclusive alligator-type belt clip.
•
MB-96N/MB-96F
LEATHER BELT HANGER
ATTACHING ACCESSORIES (Continued)
D
Belt clip
To attach:
1. Remove the battery pack from the transceiver, if it is
attached.
2. Slide the belt clip in the direction of the arrow until the
belt clip is locked and makes a ‘click’ sound.
To detach:
Lift the tab up (
1
), and slide the belt clip in the direction of
the arrow (
2
).
BE CAREFUL! DO NOT
break your fingernail
D
OTHERS
•
HM-158LA/HM-159LA/HM-168LWP
SPEAKER-
MICROPHONE
Combination speaker-microphone that provides
convenient operation while hanging the transceiver on
your belt.
•
HM-166LA
EARPHONE-MICROPHONE
Ideal for hands-free operation: clip the HM-166LA (with
integrated PTT switch) to your lapel or breast pocket.
Allows you to operate in rainy conditions.
•
FA-SC25V/FA-SC55V/FA-SC25U/FA-SC57U/
FA-SC72U/FA-SC62V/FA-SC63V/FA-SC03U
ANTENNAS
FA-SC25V: 136–150 MHz
FA-SC55V: 150–174 MHz
FA-SC25U: 400–430 MHz
FA-SC57U: 430–470 MHz
FA-SC72U: 470–520 MHz
FA-SC62V: 150–160 MHz
FA-SC63V: 155–165 MHz
FA-SC03U: 380–430 MHz
•
FA-SC56VS/FA-SC57VS/FA-SC73US
STUBBY ANTENNAS
FA-SC56VS: 150–162 MHz FA-SC57VS: 160–174 MHz
FA-SC73US: 450–490 MHz
•
FA-SC61VC/FA-SC61UC
CUT ANTENNAS
FA-SC61VC: 136–174 MHz FA-SC61UC: 380–520 MHz
•
MB-130
VEHICLE CHARGER BRACKET
Mounts the BC-160
DESKTOP CHARGER
onto variety of
places in a vehicle.
Some options may not be available in some countries. Ask
your dealer for details.
1
2
1
4
3
2
5
6 7
8
9
10
1
TRANSMIT ICON
Displayed while transmitting.
2
BUSY ICON
Displayed while the channel is busy (receiving).
3
SIGNAL STRENGTH ICON
Shows the relative receive signal strength level.
Weak
Strong
Receive signal level
About “ ” icon for the Trunking mode:
• Disappears while in a no service area.
• Blinks while registering to a repeater.
• Displayed when registration is completed.
4
LOW POWER ICON
Displayed when low output power is selected.
L
When the battery power decreases to a specified
level, low power is automatically selected.
5
AUDIBLE ICON
• In the analog mode, displayed when the CTCSS
(DTCS) squelch mute is released while holding down
[Monitor].
• In the digital mode, displayed while holding down
[Monitor].
6
ENCRYPTION ICON
In the digital mode, displayed when the encryption
function is activated.
7
BELL ICON
In the digital mode, displayed/blinks when an SDM
(Short Data Message), Status Call or Call Alert is
received, depending on the presetting.
8
KEY LOCK ICON
Displayed when the Key lock function is ON.
9
BATTERY ICON
Displayed or blinks when the battery power decreases
to a specified level.
10
ALPHANUMERIC DISPLAY
Displays an operating channel number, channel name,
User Set mode contents, and so on.
D
Regular charging with the BC-171
The optional BC-171 regularly charges the Li-ion battery
pack.
• A power adapter (may be supplied with BC-171,
depending on the version) or the DC power cable (OPC-
515L/CP-23L) is additionally required.
Battery Pack
+ Transceiver
Turn OFF
Battery
Pack
Power Adapter*
The
OPC-515L
(for a 13.8 V DC
power source)
or the CP-23L
(for a 12 V
cigarette lighter
socket) can be
used instead
of the power
adapter.
* A different type, or no power adapter is supplied,
depending on the charger version.
AD-106
Plugs
Sockets
Screws
supplied with
the charger
adapter.
D
Rapid charging with the BC-119N+AD-106
The optional BC-119N rapidly charges the Li-ion battery
pack. The following items are additionally required.
• AD-106
CHARGER ADAPTER
• A power adapter (may be supplied with the BC-119N,
depending on the version) or the DC power cable
(OPC-515L/CP-23L).
Battery Pack
+ Transceiver
Turn OFF
Battery
Pack
Power Adapter*
The
OPC-515L
(for
a 13.8 V DC power
source) or the CP-23L
(for a 12 V cigarette
lighter socket) can be
used instead of the
power adapter.
* A different type, or no power adapter is supplied,
depending on the charger version.