20
6
CLONING
CONVENTIONAL OPERATION
19
5
‘
‘
Transmitting notes
D
D
TIME-OUT TIMER
After continuous transmission for a pre-programmed period, the
time-out timer is activated, causing the transceiver to stop transmit-
ting and automatically select receive.
D
D
PENALTY TIMER
Once the time-out timer is activated, transmission is further inhibited
for a period determined by the penalty timer.
‘
‘
Cloning
Cloning allows you to quickly and easily transfer the programmed
contents from one transceiver to another transceiver; or data from
PC to a transceiver using the optional CS-F11 CLONING SOFT-
WARE.
D
D
Transceiver-to-transceiver cloning
NOTE: ‘Transceiver-to-transceiver cloning’ is available be-
tween the same models on 2CH model to 16CH model or the
opposite case cannot be cloned.
q
Connect the optional OPC-474 CLONING CABLE with adapter
plugs to the [SP] jack of the master and slave transceivers.
• The master transceiver is used to send data to the slave trans-
ceiver.
w
While pushing [PTT] and [Upper], turn the transceiver’s power
on to enter cloning mode (master transceiver only–power ON
only for slave transceiver).
e
Push [PTT] on the master transceiver.
• When cloning is finished, a “Beep” tone is emitted two times.
NOTE: DO NOT push the [PTT] on the slave transceiver during
cloning. This will cause a cloning error.
r
When cloning is finished, turn power off, then on again to return
to normal operation.
D
D
PC-to-transceiver cloning
Please refer to the HELP file that comes with the CS-F11 CLONING
SOFTWARE.
CAUTION: Imprudent cloning operation causes a cloning error.
In such a case, memory contents may be lost. Cloning must
then be repeated.