![Icom IC-F1721D Service Manual Download Page 16](http://html1.mh-extra.com/html/icom/ic-f1721d/ic-f1721d_service-manual_4203161016.webp)
5 - 2
q
: Transceiver's connection state
w
: Reload adjustment data
e
: Receive sensitivity measurement
r
: Connected DC voltage measurement
t
: PLL lock voltage measurement
y
: Operating channel select
u
: RF output power
i
: FM modulation balance (narrow)
o
: CTCSS/DTCS deviation
!0
: Squelch level
!1
: Reference frequency
!2
: Receive sensitivity (automatic)
NOTE:
!3
: PLL lock voltage for RX (automatic)
!4
: PLL lock voltage for TX (automatic)
!5
: PLL lock voltage for RX (manual)
!6
: PLL lock voltage for TX (manual)
!7
: S-meter adjustment
!8
: Digital RSSI
!9
: Deviation (narrow)
@0
: Deviation (wide/middle)
@1
: Deviation (digital)
@2
: DSP frequency
@3
: Base band frequency
@4
: 2/5 TONE deviation
The above values for settings are example only.
Each transceiver has its own specific values for each setting.
r
t
y
u
q
i
o
!0
!2
!1
!3
!4
!5
!6
!7
w
e
o
!1
!8
!9
@1
@0
@2
@3
@4
• CS-F1700 ADJ'S SCREEN EXAMPLE