4-4
4-3 RECEIVE ADJUSTMENTS
Select an adjustment item by pushing [
1.
Y
]/[
Z
].
Set or modify the adjustment value as specified by rotating [DIAL], and then push [ENT].
2.
ADJUSTMENT
ADJUSTMENT
ITEM
TRANSCEIVER'S CONDITION
OPERATION
VALUE
NO.
NAME
RECEIVE
SENSITIVITY
- AM -
1
044
BPF1
Frequency:
•
IC-A25N:
108.025 MHz
IC-A25C:
118.025 MHz
Receiving
•
Connect the SSG to the antenna
connector, and set as shown below:
Frequency:
IC-A25N:
108.025 MHz
IC-A25C:
118.025 MHz
Modulation: None
Level:
+10 dBμ
†
(−97 dBm)
Push [ENT]
(Automatic
adjustment)
2
045
BPF2
Frequency: 127.500 MHz
•
Receiving
•
Set the SSG to:
Frequency: 127.500 MHz
Level:
+5 dBμ
†
(−102 dBm)
3
046
BPF3
Frequency: 136.975 MHz
•
Receiving
•
Set the SSG to:
Frequency: 136.975 MHz
- FM -
4
047
BPF4
Frequency: 161.650 MHz
•
Receiving
•
Set the SSG to:
Frequency: 161.650 MHz
5
048
BPF5
Frequency: 163.275 MHz
•
Receiving
•
Set the SSG to:
Frequency: 163.275 MHz
SqUELCH
LEVEL
- Wide -
1
050
WSO_S
Frequency: 118.025 MHz
•
Receiving
•
Connect the SSG to the antenna
connector, and set as shown below:
Frequency: 118.025 MHz
Modulation: None
Level:
−10 dBμ
†
(−117 dBm)
Push [ENT]
(Automatic
adjustment)
2
051
WSC_S
Set the SSG to:
Level:
−13 dBμ
†
(−120 dBm)
3
052
WSO_T
Set the SSG to:
Level:
+13 dBμ
†
(−94 dBm)
4
053
WSC_T
Set the SSG to:
Level:
+10 dBμ
†
(−97 dBm)
- Narrow -
5
054
NSO_S
Frequency: 118.030 MHz
•
Receiving
•
Set the SSG to:
Level:
−10 dBμ
†
(−117 dBm)
6
055
NSC_S
Set the SSG to:
Level:
−13 dBμ
†
(−120 dBm)
7
056
NSO_T
Set the SSG to:
Level:
+13 dBμ
†
(−94 dBm)
8
057
NSC_T
Set the SSG to:
Level:
+10 dBμ
†
(−97 dBm)
- FM -
9
058
SO_S
Frequency: 162.550 MHz
•
Receiving
•
Set the SSG to:
Frequency: 162.550 MHz
Level:
−10 dBμ
†
(−117 dBm)
10
059
SC_S
Set the SSG to:
Level:
−13 dBμ
†
(−120 dBm)
11
060
SO_T
Set the SSG to:
Level:
+13 dBμ
†
(−94 dBm)
12
061
SC_T
Set the SSG to:
Level:
+10 dBμ
†
(−97 dBm)
VOR 0°
(Only for IC-A25N)
1
063
VOR0
Frequency: 108.000 MHz
•
Receiving
•
Connect the VOR tester to the
antenna connector, and set as shown
below:
Frequency: 108.000 MHz
Level:
+47 dBμ
†
(−60 dBm)
Modulation: 30 Hz
30%
9960 Hz 30%
Bearing:
0°
Push [ENT]
(Automatic
adjustment)
2nd LO
FREqUENCY
1
066
LO
Frequency: 127.510 MHz
•
Receiving
•
Connect the SSG to the antenna
connector, and set as shown below:
Frequency: 127.50833 MHz
Modulation: None
Level:
+90 dBμ
†
(−17 dBm)
Push [ENT]
(Automatic
adjustment)
†
The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.