3-7
D
Selecting 1 Hz step
The minimum tuning step of 1 Hz can be used for fine
tuning.
q
Push [TS] to turn the quick tuning function OFF.
w
Push [TS] for 1 sec. to turn the 1 Hz tuning step ON
and OFF.
NOTE:
1 Hz tuning step activates for both main and
sub bands simultaneously. Therefore, either [TS]
can be used for the 1 Hz tuning step selection.
D
Auto tuning step function
When rotating main or sub dial rapidly, the tuning
speed accelerated automatically as selected.
q
Push [EXIT/SET] several times to close a multi-
function screen, if necessary.
w
Push [F-7•SET] to select set mode menu screen.
• Pushing and holding [EXIT/SET] for 1 sec. also selects
set mode menu screen.
e
Push [F-5•OTHERS] to enter miscellaneous (oth-
ers) set mode.
r
Push [F-1•
Y
] or [F-2•
Z
] to select “MAIN DIAL Auto
TS” or “SUB DIAL Auto TS.”
• “MAIN DIAL Auto TS” for main dial, “SUB DIAL Auto TS”
for sub dial selection.
t
Rotate main dial to select the desired condition from
high, low and OFF.
• High : Approx. 5 times faster
• Low : Approx. twice faster
• OFF : Auto tuning step is turned OFF.
y
Push [EXIT/SET] to exit the set mode.
D
Band edge warning beep
When selecting a frequency, that lies outside of a band’s
specified frequency range, a warning beep sounds.
This function can be turned OFF in set mode, if de-
sired.
q
Push [EXIT/SET] several times to close a multi-
function screen, if necessary.
w
Push [F-7•SET] to select set mode menu screen.
• Pushing and holding [EXIT/SET] for 1 sec. also selects
set mode menu screen.
e
Push [F5•OTHERS] to enter miscellaneous (others)
set mode.
r
Push [F-1•
Y
] or [F-2•
Z
] to select “Beep (Band
Edge).”
t
Rotate main dial to turn the band edge warning
beep ON and OFF.
y
Push [EXIT/SET] to exit the set mode.
[F-1•
Y
] [F-2•
Z
]
[F5•OTHERS]
[EXIT/SET] [F-7•SET]
1Hz step indicator
1Hz step indicator
3
BASIC OPERATIONS