background image

10

 

CI-V commands

 

D

Command formats

 

Scope waveform data

Command:  27 00

Outputs the waveform data to the controller.

X X

X X

0 0

X X

X X

1

2

3

4

5

X X X X ...... X X

6

7

...... X X

1

: 00 (Fixed)

2

: Order of division data (Current): 01~11

3

:  Division number (Maximum): 11(USB)

 

L

When sent through theUSB port, the data is 

divided by 11 and sent in sequential order.

 

L

The 1st data sends only the wave information 

(

1

 ~ 

6

) without the waveform data (

7

). The 

2nd or later data sends the minimum wave 

information (

1

 ~ 

3

) with waveform data (

7

).

4

: Spectrum scope mode data:

 • 00 = Center mode scope

 • 01 = Fixed mode scope

 • 02 = SCROLL-C mode scope

 • 03 = SCROLL-F mode scope

5

:  Waveform information: 

The waveform information differs, depending on 

the Spectrum scope mode.

 • In the Center mode: 

Center frequency and span are sent. 

See page 19-9 of the IC-7300 FULL MANUAL 

for Operating frequency data, and the Scope 

span settings (

2

 ~ 

6

)  to the right.

 • In the Fixed, SCROLL-C, and SCROLL-F modes: 

Lower edge and higher edge frequencies are 

sent.

0 X X X X X X X X 0 X X X X X X X X 0 0

10 Hz

 digit: 

0 (Fixed)

1 Hz

 digit: 

0–

9

1 kHz

 digit: 

0–

9

100 Hz

 digit: 

0–

9

100 kHz

 digit: 

0–

9

10 kHz

 digit: 

0–

9

10 MHz

 digit: 

0–

7

1 MHz

 digit: 

0–

9

1 GHz

 digit: 

0, F

*

100 MHz

 digit: 

(Fixed)

10 Hz

 digit: 

0–

9

1 Hz

 digit: 

0–

9

1 kHz

 digit: 

0–

9

100 Hz

 digit: 

0–

9

100 kHz

 digit: 

0–

9

10 kHz

 digit:  

0–

7

10 MHz

 digit:  

0–

9

1 MHz

 digit:  

0–

9

1 GHz

 digit: 

(Fixed)

100 MHz

 digit: 

(Fixed)

Lower edge

Higher edge

  * “F” means that the Lower edge frequency is a negative value.

 

L

Entry of less than 100 Hz digits are ignored.

 

Scope span settings  

(in the Center mode and SCROLL-C mode Scope)

Command: 27 15

0 0 0 0 X X X X 0 0 0 0

1

1 kHz digit: 0, 2, 5

100 Hz digit: 0, 5

100 kHz digit: 0, 1, 2, 5

10 kHz digit: 0, 1, 2, 5 

10 Hz digit: 0 (Fixed)

1 Hz digit: 0 (Fixed)

10 MHz digit: 0 (Fixed)

1 MHz digit: 0 (Fixed)

1 GHz digit: 0 (Fixed) 100 MHz digit: 0 (Fixed)

2

3

4

5

6

0 (Fixed) 0 (Fixed)

Span (kHz)

2500

2.5

5000

5

10000

10

25000

25

50000

50

100000

100

250000

250

500000

500

 

Spectrum scope mode settings

Command: 27 14

0 0 X X

00=Center mode

01=Fixed mode

02=SCROLL-C mode

03=SCROLL-F mode

Fixed

0 0 X X

01=Edge 1

02=Edge 2

03=Edge 3

04=Edge 4

Fixed

 

Scope Edge number settings 

(in the Fixed mode and SCROLL-F mode Scope)

Command: 27 16

6

:  Out of range information:

 • 00 = In range

 • 01 = Out of range

 

L

If the scope data is out of range, the waveform 

data (

7

) is omitted.

7

:  Waveform data: 

The transceiver outputs the drawn waveform data. 

The data range or data length of the waveform 

data is judged by the controller. (The data range 

is basically the same as the display size of the 

scope on the controller.)

 • Data range: 0 ~ 160

 • Data length: 475

Summary of Contents for IC-7300

Page 1: ...1 second closes the screen Edge Lower frequency Grid frequency level When in the SCROLL C mode is displayed When in the SCROLL C mode is displayed Operating frequency moves Edge Upper frequency D DScr...

Page 2: ...nd they do not match the contents of the preset memory In Use disappears L LTouching UNLOAD returns the transceiver settings to those set before loading the preset memory NOTE You cannot load the pres...

Page 3: ...In the Memory mode selects Memory channels RF PWR Adjusts the transmit output power MIC G Adjusts the microphone gain COMP Adjusts the Speech Compressor level MONI Adjusts the audio level for the Mon...

Page 4: ...on of the readout is moved from 5 Touch the readout to display both the current local time and UTC time 5Function indicator for Multi function control The indicator is added Displays the function that...

Page 5: ...to open the PRESET screen Voice Keyer RTTY Memory 1 In the SSB AM or FM mode Push to transmit the voice audio recorded on the SD card once Hold down for 1 second to repeatedly transmit the voice audio...

Page 6: ...de L LIn the VFO or Memory mode the frequency and the operating mode are announced L LS meter level is announced only when the S level SPEECH function is ON MODE Push to select the operating mode Hold...

Page 7: ...etting of the CI V USB Port is changed from Link to REMOTE to Unlink from REMOTE MENU SET Connectors CI V CI V USB Port Firmware Update screen A dialog that recommends making a backup of the current s...

Page 8: ...ad scope edge 4 frequencies for 45 00 60 00 MHz 0216 See p 9 Send read scope edge 4 frequencies for 60 00 74 80 MHz 27 00 See p 10 Read the Scope waveform data Only when Scope ON OFF status Command 27...

Page 9: ...ce Keyer RTTY Memory 1 12 Voice Keyer RTTY Memory 2 13 Voice Keyer RTTY Memory 3 14 Voice Keyer RTTY Memory 4 15 TS 16 MPAD 17 SPLIT 18 A B 19 TUNER Bandscope edge frequency settings Command 1A 050112...

Page 10: ...0 Fixed 10 Hz digit 0 9 1 Hz digit 0 9 1 kHz digit 0 9 100 Hz digit 0 9 100 kHz digit 0 9 10 kHz digit 0 7 10 MHz digit 0 9 1 MHz digit 0 9 1 GHz digit 0 Fixed 100 MHz digit 0 Fixed Lower edge Higher...

Page 11: ...5 00 12 45 00 60 00 13 60 00 74 80 2 Selectable Edge number 01 1 02 2 03 3 04 4 q 0 X X X X w e r t y u i o 0 1 2 X X X X X X X 0 0 X X X X X X X X 0 0 10 Hz digit 0 9 1 Hz digit 0 9 1 kHz digit 0 9 1...

Page 12: ...ke a backup file of the transceiver s settings such as stored memory channels filter settings to the SD card before updating the firmware The CPU will be automatically reset when the firmware update i...

Page 13: ...and table Cmd Sub Cmd Data Description 1A 05 0196 See below Send read SSB D TX bandwidth 0197 00 01 Inhibit Timer at USB connection 00 OFF 01 ON Send read data SSB D transmission passband width settin...

Reviews: