11-3
11
CONTROL COMMAND
Controlling the radio with CI-V (Continued)
■
D
Command table
Cmd.
Sub cmd.
Data
Description
00
—
—
Send frequency data.
(for transceive operation)
01
00
—
Select LSB mode
(for transceive operation)
01
—
Select USB mode
(for transceive operation)
02
—
Select AM mode
(for transceive operation)
03
—
Select CW mode
(for transceive operation)
04
—
Select RTTY mode
(for transceive operation)
07
—
Select CW-R mode
(for transceive operation)
08
—
Select RTTY-R mode
(for transceive operation)
02
—
—
Read band edge frequencies
03
—
—
Read operating frequency
04
—
—
Read operating mode
05
—
—
Set operating frequency
06
00
—
Select LSB mode
01
—
Select USB mode
02
—
Select AM mode
03
—
Select CW mode
04
—
Select RTTY mode
07
—
Select CW-R mode
08
—
Select RTTY-R mode
07
—
—
Select VFO mode
00
—
Select VFO A
01
—
Select VFO B
A0
—
Equalize VFO A and VFO B
B0
—
Exchange VFO A and VFO B
08
—
—
Select memory mode
0001−
0201*
—
Select memory channel
*P1=0200, P2=0201
09
—
—
Memory write
0A
—
—
Memory to VFO
0B
—
—
Memory clear
0E
00
—
Scan stop
01
—
Programmed/memory scan start
02
—
Programmed scan start
22
—
Memory scan start
D0
—
Set scan resume OFF
D3
—
Set scan resume ON
0F
00
—
Turn the split function OFF
01
—
Turn the split function ON
10
00
—
Select 10 Hz (or 1 Hz) tuning steps
01
—
Select 100 Hz tuning steps
02
—
Select 1 kHz tuning step
03
—
Select 5 kHz tuning steps
04
—
Select 9 kHz tuning steps
05
—
Select 10 kHz tuning steps
11
—
0
Send/read attenuator OFF.
20
Send/read attenuator ON (20 dB).
13
00
—
Announce with voice synthesizer
01
—
( 00=all data 01=frequency and
S-meter; 02=receive mode)
02
—
Cmd.
Sub cmd.
Data
Description
14
01
0 to 255 Send/read [AF] level setting
(0=max. CCW to 255=max. CW)
02
0 to 255 Send/read [RF] level setting
(0=max. CCW to 255=11 o'clock)
03
0 to 255 Send/read [SQL] level setting
(0=11 o'clock to 255=max. CW)
06
0 to 255 Send/read NR level setting
(0=0% to 255=100%)
07
0 to 255 Send/read Inside [PBT] setting (0= max.
CCW, 128=center, 255=max. CW)
08
0 to 255 Send/read Outside [PBT] setting
( 0= max. CCW, 128=center,
255=max. CW)
09
0 to 255 Send/read CW Tone Pitch setting
(0=300 Hz to 255=900 Hz (5 Hz steps))
0A
0 to 255 Send/read RF power setting
(0=minimum to 255=100%)
0B
0 to 255 Send/read MIC gain setting
(0=0% to 255=100%)
0C
0 to 255 Send/read Key speed level setting
(0=6 wpm to 255=60 wpm)
0D
0 to 255 Send/read [MNF] setting (0=max. CCW,
128=center, 255=max. CW)
0E
0 to 255 Send/read COMP level setting
(0=0 to 255=10)
0F
0 to 255 Send/read Break-IN delay setting
(0=2.0 d to 255=13.0 dots)
12
0 to 255 Send/read NB level setting
(0=0% to 255=100%)
16
0 to 255 Send/read VOX gain setting
(0=0% to 255=100%)
17
0 to 255 Send/read Anti VOX gain setting
(0=0% to 255=100%)
15
01
—
Read squelch status
02
—
Read S-meter level
11
—
Read RF power meter
12
—
Read SWR meter
13
—
Read ALC meter
16
02
0
Send/read Preamp OFF
1
Send/read Preamp ON
12
0
Send/read AGC OFF
1
Send/read AGC Fast
2
Send/read AGC Slow
22
0
Send/read Noise Blanker OFF
1
Send/read Noise Blanker ON
40
0
Send/read Noise Reduction OFF
1
Send/read Noise Reduction ON
41
0
Send/read Auto Notch function OFF
1
Send/read Auto Notch function ON
44
0
Send/read Speech compressor OFF
1
Send/read Speech compressor ON
46
0
Send/read VOX function OFF
1
Send/read VOX function ON
47
0
Send/read Break-IN function OFF
1
Send/read Semi Break-IN function ON
2
Send/read Full Break-IN function ON
48
0
Send/read Manual Notch function OFF
1
Send/read Manual Notch function ON
4F
0
Send/read Twin Peak Filter OFF
1
Send/read Twin Peak Filter ON
50
0
Send/read Dial lock function OFF
1
Send/read Dial lock function ON
19
00
—
Read the transceiver ID
1A
00
See p. 11-6 Send/read memory contents
01
See p. 11-5 Send/read band stacking register con-
tents
Previous view