47
7
SET MODE
■
General
Set mode is used for programming infrequently
changed values or conditions of functions. The IC-
706MKIIG has 2 separate set modes:
quick set mode
and
initial set mode.
D
Quick set mode operation
➀
While power is ON, push [DISPLAY] for 2 sec.
• Quick set mode is selected and one of its items appears.
• Quick set mode items vary depending on the operating
mode (SSB, FM, etc.) selected.
➁
Push [MENU] one or more times to select the
desired item.
• [M-CH] or [
Y
]/[
Z
] can also be used.
➂
Rotate the main dial to set the values or conditions
for the selected item.
➃
Repeat steps
➁
and
➂
to set other items.
➄
To exit quick set mode, push [DISPLAY] momentar-
ily.
D
Initial set mode operation
➀
Push [POWER] for 2 sec. to turn power OFF.
➁
While pushing [LOCK] push [POWER] to turn power
ON.
• Initial set mode is selected and one of its items appears.
➂
Push [MENU] one or more times to select the
desired item.
• [M-CH] or [
Y
]/[
Z
] can also be used.
➃
Rotate the main dial to set the values or conditions
for the selected item.
➄
Repeat steps
➂
and
➃
to set other items.
➅
To exit initial set mode, push [POWER] for 2 sec. to
turn power OFF.
➆
Push [POWER] to turn power ON again.
• The conditions selected in initial set mode are now effec-
tive.
[POWER]
[MENU]
[LOCK]
Main dial
Item number
Item
Value or
condition
1 MODE SELECT
[DISPLAY EXAMPLE: INITIAL SET MODE]
[M-CH]
[
Y
]
[
Z
]
Q1
RF POWER
USB
[POWER]
[MENU]
[M-CH]
[DISPLAY]
Main dial
[
Y
]
[
Z
]
Item number
Item
Value or
condition
[DISPLAY EXAMPLE: QUICK SET MODE]
P
O
S1
5
5
3
7
9
20
40
10
60dB