1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan
A-7022D-3EX-
q
Printed in Japan
© 2012 Icom Inc.
¤3
Received Call Log
The transceiver automatically stores up to 50 distress mes
-
sages and 50 other messages, and they can be used as a
supplement to your logbook.
• While in the normal operating mode, “
” blinks in the upper
right corner of the LCD when there is an unread message.
Push [LOG] to enter “RCVD CALL LOG” in the DSC CALLS
q
menu, or you can enter it through the Menu screen.
Select “Distress” or “Others.”
w
• The Distress messages are stored in “Distress.”
• The messages other than the Distress are stored in “Others.”
• “
” appears when there are unread messages.
• “
” appears when there are no unread messages.
• No icon appears when there are no messages.
Select the desired message.
e
• The message in the unopened file has not been read.
Rotate Dial to scroll the message contents.
r
To delete the displayed message, push [DEL].
t
• A confirmation screen appears, then push [OK] to delete.
Push [EXIT] to return to the normal operating mode.
y
¤5
DSC Settings
Automatic Acknowledgement
D
Enter
q
either “INDIVIDUAL ACK,” “POSITION ACK” or “TEST
ACK” in the DSC Settings menu.
Rotate Dial
w
to select “Auto TX” or “Manual TX,” then push
[ENT].
• Push [BACK] to cancel and return to the DSC Settings menu.
Push [EXIT] to return to the normal operating mode.
e
Channel 16 Switch function
D
Enter “CH 16 SWITCH”
q
in the DSC Settings menu.
Rotate Dial to set the Channel 16 Switch function to “Auto
w
(No Delay),” “10 Second Delay” or “OFF
,” then push [ENT].
• Push [BACK] to cancel and return to the DSC Settings menu.
Push [EXIT] to return to the normal operating mode.
e
DSC Data Output
D
Enter “DSC DATA OUTPUT”
q
in the DSC Settings menu.
Rotate Dial to set the DSC Data Output function to “All Sta-
w
tion,” “List Station” or “OFF,” then push [ENT].
• Push [BACK] to cancel and return to the DSC Settings menu.
Push [EXIT] to return to the normal operating mode.
e
Alarm
D
Enter “ALARM”
q
in the DSC Settings menu.
Rotate Dial to select
w
the status, then push [ENT].
• Push [BACK] to cancel and return to the DSC Settings menu.
• “ Safety,” “Routine,” “Warning,” “Self-Terminate” and “Discrete”
are selectable. (default: ON )
Rotate Dial to set the Alarm setting to “ON” or “OFF.”
e
Push [EXIT] to return to the normal operating mode.
r
Channel 70 Squelch level
D
Enter “CH 70 SQL LEVEL”
q
in the DSC Settings menu.
Rotate Dial to adjust the squelch level until the noise just
w
disappears, then push [ENT].
• Push [BACK] to cancel and return to the DSC Settings menu.
Push [EXIT] to return to the normal operating mode.
e
DSC Loop Test
D
Enter “DSC LOOP TEST”
q
in the DSC Settings menu.
Push [ENT] to start the DSC loop test.
w
• Push [BACK] to cancel and return to the DSC Settings menu.
• When the transmit DSC and receive DSC signals are matched,
“OK” appears.
Push [EXIT] to return to the normal operating mode.
e
If “NG” appears in step
w
, either or both TX and RX DSC
circuits has a problem. In that case, you will have to send
the transceiver to your nearest dealer for repair.
¤4
Transmitted Call Log
The transceiver automatically stores up to 50 transmitted calls,
and the logs can be used as a supplement to your logbook.
Enter “TX CALL LOG” in the DSC CALLS menu.
q
Select the desired message.
w
Rotate Dial to scroll the message contents.
e
To delete the displayed message, push [DEL].
r
• The confirmation screen appears, then push [OK] to delete.
Push [EXIT] to return to the normal operating mode.
t
Receiving a Test Call
D
Push [ALARM OFF] to stop the alarm and the blinking back-
q
light.
• If [ALARM OFF] is not pushed within 2 minutes, the next
screen may appear, depending on the call Category.
Push a softkey to select your desired action.
w
[IGN]
Push to ignore the call and return to the normal operating
mode.
[INFO]
Push to display the Received Call information. (See
¤3
)
[ACK]
Push to display the “TEST ACK” screen to reply to the call.
(See
¤1
)
When “TEST ACK” is set to “Auto TX,” the transceiver
automatically replies to the call. In that case, both the TX
and RX calls are stored in the Transmitted and Received
Call Logs.
Receiving a Test Acknowledgement Call
D
Push [ALARM OFF] to stop the alarm and the blinking back-
q
light.
• If [ALARM OFF] is not pushed within 2 minutes, the next
screen may appear, depending on the call Category.
Push [EXIT] to return to the normal operating mode.
w
¤2
Receiving DSC calls (Continued)
¤6
Intercom operation
This function is not available with the IC-M400BB.
Push [INCM] to enter the Intercom mode.
q
Hold down [INCM CALL] to sound the intercom beeps.
w
• The transceiver and the command microphone sound beeps
while holding down [INCM CALL].
• “CALL” appears.
After releasing [INCM CALL], hold down [PTT] and speak
e
into the microphone at a normal voice level.
• “TALK” appears on the caller’s display, or “LSTN” appears on
the listener’s display.
• To adjust the HM-195’s intercom volume level, rotate [VOL/
SQL](Dial) on the HM-195.
After releasing [PTT] you can hear the response through
r
the speaker.
To return to the normal operating mode, push [EXIT].
t
¤7
RX Speaker function
Push [RX
q
] to enter the RX Speaker mode.
• The RX Speaker volume level adjustment screen is displayed.
Rotate Dial or push [
w
Y
]/[
Z
]/[
Ω
]/[
≈
] to adjust the RX Speak-
er volume level, and then push [ENT].
• “RX
” appears.
To return to normal operating mode, push [RX
e
].
• “RX
” disappears.
¤8
PA (Public Address) function
Push [PA] to enter the Public Address mode.
q
Hold down [PTT] and speak at a normal voice level.
w
• While holding down [PTT], the screen below is displayed.
• To adjust the PA volume level, rotate Dial.
Push [EXIT] to return to normal operating screen.
e
¤9
Horn function
Push [HORN] to enter the Horn mode.
q
Hold down [HORN] to sound a horn.
w
• While holding down [HORN], the horn sounds, and the screen
below is displayed.
• To adjust the horn volume level, rotate Dial.
Push [EXIT] to return to the normal operating screen.
e
‹0
Menu screen operation
The Menu screen is used to change the transceiver’s functions
and the microphone’s own functions, send DSC calls or show
the programmed MMSI and ATIS*
1
codes and GPS informa-
tion*
2
.
*
1
Appears only when the transceiver is the Dutch or German ver-
sion.
*
2
Appears only when a GPS receiver compatible with NMEA0183
ver. 2.0 or 3.01 is connected to the transceiver.
These instructions are for only the microphone’s own func-
tions. Refer to the transceiver’s manual for the settings of
the other functions. (Some functions cannot be selected
from the HM-195.)
D
Entering the Menu screen and operation
Push [MENU].
q
Rotate Dial or push [
w
∫
]/[
√
] to select the root item, and then
push [ENT].
Rotate Dial or push [
e
∫
]/[
√
] to select the desired item, and
then push [ENT].
Rotate Dial or push [
r
∫
]/[
√
] to select the option, and then
push [ENT] to set it.
t
Push [EXIT] to exit the Menu screen.
• Push [CLEAR] or [BACK] to return to the previous screen.
•
Backlight
The function display and keys of the HM-195 can be backlit for
better visibility under low light conditions.
The backlight can be set to 7 levels and OFF.
(Default: 7)
•
Display contrast
The contrast of the HM-195’s function display can be adjusted
in 8 steps.
Level 1 is the lowest contrast, and level 8 is the highest con
-
trast.
(Default: 5)
•
Key Beep
You can turn OFF beep tones for silent operation, or you can
turn ON the tones to have confirmation beeps sound when a
key is pushed.
(Default: ON)
•
COMMANDMIC Speaker
The HM-195’s external speaker can be used instead of the in
-
ternal speaker.
(Default: Internal Speaker)
Regardless of this setting, the transceiver’s microphone
speaker is ON.
On the caller’s display
On the listener’s display
When “Distress” is selected in step
w
.
+
See “Instructions
q
” (
z
to
⁄5
)
or “Instructions
w
” (
⁄6
to
¤1
)
for other functions.