 Received Call Log

The  transceiver  automatically  stores  up  to  50  distress  mes

-

sages  and  50  other  messages,  and  they  can  be  used  as  a 

supplement to your logbook.

•  While  in  the  normal  operating  mode, “ 

  ”  blinks  in  the  upper 

right corner of the LCD when there is an unread message.

 Push [LOG] to enter “RCVD CALL LOG” in the DSC CALLS 

 

q

menu, or you can enter it through the Menu screen.
 Select “Distress” or “Others.”

 

w

  • The Distress messages are stored in “Distress.”
  • The messages other than the Distress are stored in “Others.”
  • “ 

 ” appears when there are unread messages.

  • “ 

 ” appears when there are no unread messages.

  • No icon appears when there are no messages.

 Select the desired message.

 

e

  •  The message in the unopened file has not been read.

Rotate Dial to scroll the message contents.

 

r

 To delete the displayed message, push [DEL].

 

t

  •  A confirmation screen appears, then push [OK] to delete.

 Push [EXIT] to return to the normal operating mode.

 

y

¤5

 DSC Settings

Automatic Acknowledgement

 

D

 Enter

 

q

 either “INDIVIDUAL ACK,” “POSITION ACK” or “TEST 

ACK” in the DSC Settings menu.
 Rotate  Dial 

 

w

to  select “Auto TX”  or “Manual TX,”  then  push 

[ENT].

  •  Push [BACK] to cancel and return to the DSC Settings menu.

 Push [EXIT] to return to the normal operating mode.

 

e

Channel 16 Switch function

 

D

  Enter “CH 16 SWITCH” 

 

q

in the DSC Settings menu.

 Rotate Dial to set the Channel 16 Switch function to “Auto 

 

w

(No Delay),” “10 Second Delay” or “OFF

,” then push [ENT].

  •  Push [BACK] to cancel and return to the DSC Settings menu.

 Push [EXIT] to return to the normal operating mode.

 

e

DSC Data Output

 

D

 Enter “DSC DATA OUTPUT” 

 

q

in the DSC Settings menu.

 Rotate Dial to set the DSC Data Output function to “All Sta-

 

w

tion,” “List Station” or “OFF,” then push [ENT].

  •  Push [BACK] to cancel and return to the DSC Settings menu.

 Push [EXIT] to return to the normal operating mode.

 

e

Alarm

 

D

  Enter “ALARM” 

 

q

in the DSC Settings menu.

 Rotate Dial to select 

 

w

the status, then push [ENT].

  •  Push [BACK] to cancel and return to the DSC Settings menu.
  • “ Safety,” “Routine,” “Warning,” “Self-Terminate” and “Discrete” 

are selectable. (default: ON )

 Rotate Dial to set the Alarm setting to “ON” or “OFF.”

 

e

 Push [EXIT] to return to the normal operating mode.

 

r

Channel 70 Squelch level

 

D

  Enter “CH 70 SQL LEVEL” 

 

q

in the DSC Settings menu.

 Rotate Dial to adjust the squelch level until the noise just 

 

w

disappears, then push [ENT].

  •  Push [BACK] to cancel and return to the DSC Settings menu.

 Push [EXIT] to return to the normal operating mode.

 

e

DSC Loop Test

 

D

  Enter “DSC LOOP TEST” 

 

q

in the DSC Settings menu.

 Push [ENT] to start the DSC loop test.

 

w

  •  Push [BACK] to cancel and return to the DSC Settings menu.
  •  When the transmit DSC and receive DSC signals are matched, 

“OK” appears.

 Push [EXIT] to return to the normal operating mode.

 

e

If “NG” appears in step 

w

, either or both TX and RX DSC 

circuits has a problem. In that case, you will have to send 
the transceiver to your nearest dealer for repair. 

¤4

 Transmitted Call Log

The transceiver automatically stores up to 50 transmitted calls, 

and the logs can be used as a supplement to your logbook.

 Enter “TX CALL LOG” in the DSC CALLS menu.

 

q

 Select the desired message.

 

w

Rotate Dial to scroll the message contents.

 

e

 To delete the displayed message, push [DEL].

 

r

  •  The confirmation screen appears, then push [OK] to delete.

 Push [EXIT] to return to the normal operating mode.

 

t

Receiving a Test Call

 

D

 Push [ALARM OFF] to stop the alarm and the blinking back-

 

q

light.

  •  If  [ALARM  OFF]  is  not  pushed  within  2  minutes,  the  next 

screen may appear, depending on the call Category.

 Push a softkey to select your desired action.

 

w

   [IGN]
   Push  to  ignore  the  call  and  return  to  the  normal  operating 

mode.

   [INFO]
   Push to display the Received Call information. (See 

¤3

)

  [ACK]
   Push  to  display  the  “TEST  ACK”  screen  to  reply  to  the  call. 

(See 

¤1

)

 

 

When “TEST  ACK”  is  set  to “Auto TX,”  the  transceiver 
automatically replies to the call. In that case, both the TX 
and RX calls are stored in the Transmitted and Received 
Call Logs.

Receiving a Test Acknowledgement Call

 

D

 Push [ALARM OFF] to stop the alarm and the blinking back-

 

q

light.

  •  If  [ALARM  OFF]  is  not  pushed  within  2  minutes,  the  next 

screen may appear, depending on the call Category.

 Push [EXIT] to return to the normal operating mode.

 

w

¤2

 Receiving DSC calls (Continued)

¤6

 Intercom operation

This function is not available with the IC-M400BB.

 Push [INCM] to enter the Intercom mode.

 

q

 Hold down [INCM CALL] to sound the intercom beeps.

 

w

  •  The transceiver and the command microphone sound beeps 

while holding down [INCM CALL].

  •  “CALL” appears.

 After releasing [INCM CALL], hold down [PTT] and speak 

 

e

into the microphone at a normal voice level.

  •  “TALK” appears on the caller’s display, or “LSTN” appears on 

the listener’s display.

  •  To  adjust  the  HM-195’s  intercom  volume  level,  rotate  [VOL/

SQL](Dial) on the HM-195.

 After  releasing  [PTT]  you  can  hear  the  response  through 

 

r

the speaker.

 To return to the normal operating mode, push [EXIT].

 

t

¤7

 RX Speaker function

 Push [RX

 

q

 

] to enter the RX Speaker mode.

  •  The RX Speaker volume level adjustment screen is displayed.

 Rotate Dial or push [

 

w

Y

]/[

Z

]/[

]/[

] to adjust the RX Speak-

er volume level, and then push [ENT].

  • “RX 

 ” appears.

 To return to normal operating mode, push [RX

 

e

 

].

  • “RX 

 ” disappears.

¤8

 PA (Public Address) function

Push [PA] to enter the Public Address mode.

 

q

 Hold down [PTT] and speak at a normal voice level.

 

w

  •  While holding down [PTT], the screen below is displayed.
  • To adjust the PA volume level, rotate Dial.

 Push [EXIT] to return to normal operating screen.

 

e

¤9

 Horn function

Push [HORN] to enter the Horn mode.

 

q

 Hold down [HORN] to sound a horn.

 

w

  •  While holding down [HORN], the horn sounds, and the screen 

below is displayed.

  • To adjust the horn volume level, rotate Dial.

 Push [EXIT] to return to the normal operating screen.

 

e

‹0

 Menu screen operation

The Menu screen is used to change the transceiver’s functions 
and the microphone’s own functions, send DSC calls or show 
the  programmed  MMSI  and  ATIS*

1

  codes  and  GPS  informa-

tion*

2

.

*

1

  Appears only when the transceiver is the Dutch or German ver-

sion.

*

2

  Appears only when a GPS receiver compatible with NMEA0183 

ver. 2.0 or 3.01 is connected to the transceiver.

These instructions are for only the microphone’s own func-
tions. Refer to the transceiver’s manual for the settings of 
the  other  functions.  (Some  functions  cannot  be  selected 

from the HM-195.)

 

D

Entering the Menu screen and operation

Push [MENU].

 

q

 Rotate Dial or push [

 

w

]/[

] to select the root item, and then 

push [ENT].
 Rotate Dial or push [

 

e

]/[

] to select the desired item, and 

then push [ENT].
 Rotate Dial or push [

 

r

]/[

] to select the option, and then 

push [ENT] to set it.
 

 

t

Push [EXIT] to exit the Menu screen.

  •  Push [CLEAR] or [BACK] to return to the previous screen.

 Backlight

The function display and keys of the HM-195 can be backlit for 

better visibility under low light conditions.

The backlight can be set to 7 levels and OFF.  

(Default: 7)

 Display contrast

The contrast of the HM-195’s function display can be adjusted 
in 8 steps.
Level 1 is the lowest contrast, and level 8 is the highest con

-

trast.    

(Default: 5)

 Key Beep

You can turn OFF beep tones for silent operation, or you can 
turn ON the tones to have confirmation beeps sound when a 
key is pushed.  

(Default: ON)

 COMMANDMIC Speaker

The HM-195’s external speaker can be used instead of the in

-

ternal speaker.  

(Default: Internal Speaker)

Regardless  of  this  setting,  the  transceiver’s  microphone 
speaker is ON.

On the caller’s display

On the listener’s display

When “Distress” is selected in step 

w

.

+

See “Instructions 

q

” (

z

 to 

⁄5

)

 or “Instructions 

w

” (

⁄6

 to 

¤1

)

 for other functions.

Summary of Contents for HM-195B

Page 1: ...appears during Tri watch See 5 8 LOCAL ICON See n Appears when the Attenuator function is turned ON Only U S A and Australian version transceivers x Function display The HM 195 remotely controls the transceiver and provides an Intercom function q DISTRESS KEY DISTRESS See 9 Hold down for 3 seconds to transmit a Distress call w PTT SWITCH PTT Hold down to transmit release to receive See n e MENU KE...

Page 2: ...r draining function clears water away from the speaker grill Without this function water may muffle the sound coming from the speaker A buzzing sound is heard when this function is activated While holding down AQUA the AquaQuake function is ac tivated to clear water away from the speaker grill While holding down AQUA a low buzzing sounds to drain water regardless of the volume level setting The HM...

Page 3: ...ighting blink DSC channel Channel 70 is automatically selected and the Distress call is transmitted After transmitting the call the transceiver waits for an ac e e knowledgment call Push RESEND to manually transmit the Distress repeat call Push Ω then push INFO to display the transmitted Dis tress call information Push Ω then push PAUSE to pause the Call repeat mode push RESUME to resume it After ...

Page 4: ... the squelch correctly Transmitting an Individual Call D D Enter INDIVIDUAL CALL in the DSC CALLS menu q q Select or enter the desired individual address w w Select Routine Safety or Urgency as the desired call type e e NOTE When a coast station is selected in step w the voice channel is automatically specified by the coast station Therefore skip step r and go directly to step t Select a desired i...

Page 5: ...oftkey to select your desired action w w IGN Push to ignore the call and return to the normal operating mode INFO Push to display the Received Call information See 3 ACPT Push to monitor the channel specified by the calling station for its announcement Receiving an All Ships Call D D Push ALARM OFF to stop the alarm and the blinking back q q light If ALARM OFF is not pushed within 2 minutes the ne...

Page 6: ...eturn to the normal operating mode INFO Push to display the Received Call information See 3 ACK Push to display the TEST ACK screen to reply to the call See 1 When TEST ACK is set to Auto TX the transceiver automatically replies to the call In that case both the TX and RX calls are stored in the Transmitted and Received Call Logs Receiving a Test Acknowledgement Call D D Push ALARM OFF to stop the...