1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan
A-6496X-1EX-
w
Printed in China
© 2006 Icom Inc.
Transmitting DSC calls (continued)
D
D
Transmitting a position report reply call
“
P
PO
OS
S R
Re
ep
po
or
rt
t R
Re
ep
pl
ly
y
” item appears after a position report
call is received.
q
Select and enter “
P
PO
OS
S R
Re
ep
po
or
rt
t R
Re
ep
pl
ly
y
” in the DSC
menu.
w
Select and enter the desired individual address.
e
Push [ENT] to transmit the position report reply call.
D
D
Transmitting a polling request call
q
Select and enter “
P
Po
ol
ll
li
in
ng
g R
Re
eq
qu
ue
es
st
t
” in the DSC
menu.
w
Select and enter the desired individual address.
e
Push [ENT] to transmit the polling request call.
r
Push [CLR] to return to the previous indication before en-
tering the DSC menu.
• Even if [CLR] hasn’t been pushed, the display automatically
returns to the previous indication after 2 sec. of inactivity.
D
D
Transmitting a polling request reply call
“
P
Po
ol
ll
li
in
ng
g R
Re
ep
pl
ly
y
” item appears after a polling request call
is received.
q
Select and enter “
P
Po
ol
ll
li
in
ng
g R
Re
ep
pl
ly
y
” in the DSC menu.
w
Select and enter the desired individual address.
e
Push [ENT] to transmit the polling request call.
DSC Set mode (continued)
• After entering an 8-digit ID code, push [ENT] or [16•9] to enter
the ID name.
• 1st digit ‘0’ is fixed for a group ID.
e
After inputting, push [ENT] to program.
r
Push [CLR] or select “Exit” in the set up menu then push
[ENT].
• Returns to the DSC menu.
• Repeat again to return to the normal operation condition.
D
D
Deleting Individual ID/Group ID
q
Select and enter “
D
DE
EL
L:
:I
IN
ND
DV
V I
ID
D
” or “
D
DE
EL
L:
:G
Gr
ro
ou
up
p I
ID
D
”
in the set up menu.
w
Select the desired ID name for deleting.
e
Push [ENT] to delete the address ID and return to the set
up menu.
r
Push [CLR], or select “
E
Ex
xi
it
t
” in the set up menu then push
[ENT].
• Returns to the DSC menu.
• Repeat again to return to the normal operation condition.
D
D
Offset time
q
Select and enter “
O
Of
ff
fs
se
et
t T
Ti
im
me
e
” in the set up menu.
w
Rotate [SELECTOR] to set the offset time from the UTC
(Universal Time Coordinated) time.
• Push [16•9] or [CH/WX] to move the cursor forward or
backward, respectively.
• Push [CLR] to cancel and return to the set up menu.
e
Push [ENT] to program and return to the set up menu.
D
D
MMSI code check
The 9-digit MMSI (DSC self ID) code can be checked.
q
Select and enter “
M
MM
MS
SI
I C
Ch
he
ec
ck
k
” in the set up menu.
w
Check the 9-digit MMSI (DSC self ID) code.
e
Push [CLR], or select “
E
Ex
xi
it
t
” in the set up menu then push
[ENT].
• Returns to the DSC menu.
• Repeat again to return to the normal operation condition.
D
D
Automatic acknowledgement
q
Select and enter “
A
Au
ut
to
o A
AC
CK
K
” in the set up menu.
w
Turn the automatic acknowledgement function ON or OFF.
e
Push [ENT] to set the condition.
• Push [CLR] to cancel and return to the set up menu.
D
D
NMEA Output
When receiving position acknowledgment, the transceiver out-
puts it to the external equipment via the NMEA connector.
q
Select and enter “
N
NM
ME
EA
A O
Ou
ut
tp
pu
ut
t
” in the set up menu.
w
Select the NMEA Output function.
e
Push [ENT] to set the condition.
• Push [CLR] to cancel and return to the set up menu.
• List Station : Outputs the position data from the specified
vessels listed on the DSC individual ID screen.
• All Station : Outputs the position data from all vessels.
• OFF
: Does not output any position data to external
equipment.
¤5
Received messages
The transceiver automatically stores up to 20 distress mes-
sages and 20 other messages. The messages can be used as
an assistance to the logbook.
q
Select and enter “
R
Re
ec
ce
ei
iv
ve
ed
d C
Ca
al
ll
ls
s
” in the DSC menu.
w
Select and enter “
D
Di
is
st
tr
re
es
ss
s
” or “
O
Ot
th
he
er
r
.”
e
Select and enter the desired message.
• Messages which are blinking have not been read.
r
Rotate [SELECTOR] to scroll in the message.
t
Push [CLR] to exit or push [CLR] for 1 sec. to delete the
displayed message and return to the DSC menu.
¤6
DSC Set mode
q
Select and enter “
S
Se
et
t u
up
p
” in the DSC menu.
w
Select and enter the desired item.
e
Select and enter the desired setting or condition.
• Push [CLR] to cancel before pushing [ENT].
r
Push [CLR], or select “
E
Ex
xi
it
t
” in the set up menu then push
[ENT].
• Returns to the DSC menu.
• Repeat again to return to the normal operation condition.
D
D
Programming Individual ID/Group ID
q
Select and enter “
A
Ad
dd
d:
:I
IN
ND
DV
V I
ID
D
” or “
A
Ad
dd
d:
:G
Gr
ro
ou
up
p I
ID
D
”
in the set up menu.
w
Rotate [SELECTOR] to set the individual ID and ID name
(or group ID and ID name).
• Push [16•9] or [CH/WX] to move the cursor forward or back-
ward, respectively.
• Push [CLR] to cancel and return to the set up menu.
• “
F
Fu
ul
ll
l I
ID
D
” appears when all of the DSC address IDs are al-
ready set.
[For individual ID]
• After inputting the 9-digit MMSI number, push [ENT] or [16•9]
to enter the ID name.
• 1st digit must not be ‘0’ for a individual ID.
[For Group ID]
• The group ID is a unique number that you create for your
group. The ID name is an associated text name for that group.
CLEAN THE HM-162B/SW THOROUGHLY WITH FRESH
WATER after exposure to water including salt water, oth-
erwise, the keys and switch may become inoperable due to
salt crystallization.