background image

9

SOFTWARE ADJUSTMENT-Continued

TRACKING
(Middle2
band)
[Tr]

(High band)
[Tr]

S-METER
[SL]

9

10

11

12

13

14

15

1

2

3

4

• Operating frequency

: 400.1 MHz

• Connect an SSG to the antenna connector and set as

Level

: 1 µV* (–107 dBm)

Modulation

: 1 kHz

Deviation

: ± 3.5 kHz

• Receiving

• Operating frequency

: 429.9 MHz

• Receiving

• Operating frequency

: 480.1 MHz

• Receiving

• Operating frequency

: 549.9 MHz

• Receiving

• Operating frequency

: 810.1 MHz

• Connect an SSG to the antenna connector and set as

Level

: 1 µV* (–107 dBm)

Modulation

: 1 kHz

Deviation

: ± 3.5 kHz

• Receiving

• Operating frequency

: 905.1 MHz

• Receiving

• Operating frequency

: 999.9 MHz

• Receiving

• Operating frequency

: 146.1 MHz

• Connect an SSG to the antenna connector and set as

Level

: 1 µV* (–107 dBm)

Modulation

: 1 kHz

Deviation

: ± 3.5 kHz

• Receiving

• Operating frequency

: 445.1 MHz

• Receiving

• Operating frequency

: 435.9 MHz

• Receiving

• Operating frequency

: 810.1 MHz

• Set an SSG as

Level

: 5.6 µV* (–92 dBm)

Modulation

: 1 kHz

Deviation

: ± 3.5 kHz

• Receiving

• Push the [BAND] key.

• Push the [BAND] key.

• Push the [BAND] key.

• Push the [BAND] key.

• Push the [BAND] key.

• Push the [BAND] key.

• Push the [BAND] key.

• Push the [BAND] key.

• Push the [BAND] key.

• Push the [BAND] key.

• Push the [BAND] key.

ADJUSTMENT

ADJUSTMENT CONDITION 

OPERATION

*This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.