background image

Troubleshooting

Symptom

Problem

Unit fails to start

Check the following: wiring, voltage between pins 3 and 4. If voltage is not present; check the 

thermostat and the appropriate fuses or circuit breaker.

No Spark

Check the following: wiring, spark cable connection. Verify the spark electrode is not shorted (there 

should be 1/8” gap between the center rod and the electrode).

Gas Valve does not 

open

Verify voltage between pins 2 and 6. If voltage is present, check gas valve for incorrect wiring and 

defects.  If voltage is not present, check polarity of L1 and L2 connections.

Flame not recognized Remove the heat call and check the following: polarity of L1 and L2 connections, gas supply, spark 

wiring, flame sense wiring and the burner ground connection. Clean the flame rod. Initiate a call for 

heat and ensure a steady flame is enveloping the flame rod.

ONE-YEAR LIMITED WARRANTY

The Seller warrants its products against defects in material or workmanship for a period of one (1) year from the date of 

manufacture. The liability of the Seller is limited, at its option, to repair, replace or issue a non-case credit for the purchase prices 

of the goods which are provided to be defective. The warranty and remedies set forth herein do not apply to any goods or parts 

thereof which have been subjected to misuse including any use or application in violation of the Seller’s instructions, neglect, 

tampering, improper storage, incorrect installation or servicing not performed by the Seller. In order to permit the Seller to properly 

administer the warranty, the Buyer shall: 1) Notify the Seller promptly of any claim, submitting date code information or any other 

pertinent data as requested by the Seller. 2) Permit the Seller to inspect and test the product claimed to be defective. Items claimed 

to be defective and are determined by Seller to be non-defective are subject to a $30.00 per hour inspection fee. This warranty 

constitutes the Seller’s sole liability hereunder and is in lieu of any other warranty expressed, implied or statutory. Unless otherwise 

stated in writing, Seller makes no warranty that the goods depicted or described herein are fit for any particular purpose.

7313 William Barry Blvd., North Syracuse,  NY  13212

(

Toll Free

) 800-365-5525     (

Phone

) 315-233-5266

www.icmcontrols.com

LIAF272

Wiring Diagrams

Burner

SPARK

Burner Ground

Remote 

Flame Sense

7

6

5

4

3

2

1

Gas 

Valve

Burner

Spark

Burner Ground

7

6

5

4

3

2

1

L2

120 VAC

Thermostat

L1

Gas 

Valve

1  Burner ground

2  Gas valve hot

3  L2 (neutral)

4  L1 (120 VAC hot)

5 N/A

6  Gas valve neutral 

7  Remote flame sense

Pin # and Description