15
INFORMATION FOR PROPANE (G31) BOILERS
46
The following instructions, specific to Propane boilers, must be read in conjunction with the standard
Installation and Servicing instructions in this manual.
15.1
NOMINAL BOILER RATINGS - Propane (G31)
Propane (G31) at 37 mbar
Heat Output
Heat Input
Burner pressure
Gas rate
kW
Btu/h
kW
Btu/h
mbar
in wg
m
3
/h
12.21
41 650
15.22
51 900
7.7
3.1
0.57
18.09
61 700
23.55
76 950
15.5
6.2
0.85
28.40
96 900
33.59
114 000
35.6
14.3
1.26
15.2 REGULATIONS TO COMPLY WITH
As section 2.2 with the following addition:-
BS 5482:1:1994
Domestic propane gas burning installations at permanent dwellings
15.3 GAS SUPPLY
The maximum propane requirement of the boiler is 1.26 m³/h.
The gas storage vessel and supply pipes must be capable of delivering this quantity of gas in addition to the
demand from any other appliances in the house. A 22 mm supply pipe will be necessary for the majority of
installations, but reference should be made to BS 5482:1994 for detailed guidance on gas pipe sizing.
The regulator should ensure a dynamic pressure of 37 mbar at the inlet of the gas valve in the boiler.
The complete installation must be tested for gas soundness and purged as described in BS 5482.
All screwed gas fittings must be made using an approved propane sealant.
15.4 BOILER LOCATION
Boilers using propane must not be installed in basements or cellars.
15.5 REPLACEMENT OF PARTS
When replacing the main driver board set the gas jumper (JP1) to position 1 and 2, see wiring diagram
section 10.2.
The burner injectors are size 75, (15 off), part no.18011102.
Summary of Contents for RIO 140
Page 33: ...10 WIRING DIAGRAMS 33 10 1 ILLUSTRATED WIRING DIAGRAM ...
Page 34: ...10 WIRING DIAGRAMS 34 10 2 FUNCTIONAL FLOW WIRING DIAGRAM ...
Page 35: ...11 SEQUENCE OF OPERATION CHARTS 35 11 1 AUTOMATIC IGNITION SEQUENCE ...
Page 36: ...11 SEQUENCE OF OPERATION CHARTS 36 11 2 OPERATION IN CENTRAL HEATING MODE ...
Page 37: ...11 SEQUENCE OF OPERATION CHARTS 37 11 3 OPERATION IN DOMESTIC HOT WATER MODE ...
Page 47: ...NOTE 47 ...
Page 54: ...6 ELECTRONIC TIMER Description of controls see Figs 3 and 4 ...