background image

 

Ver 1.0

 

User

s Manual

 

Blood Pressure Monitor

 

 

 
 

 

 

 

Thank you very much for selecting iChoice Blood Pressure Monitor

 

LS805-B.

 

Please do read 

the user 

manual 

carefully and 

thoroughtly so as to ensure

 

the safe usage of this product, and keep the 

manual well for further

 

reference in case you have problems.

 

Arm Type

 

Contains FCC ID: OU9AW8001-LS 

© 2016 Beijing Choice Electronic Technology Co.,Ltd. 

ALL RIGHTS RESERVED 

Revised Date: June 18, 2016 

Ver 1.0 

Summary of Contents for LS805-B

Page 1: ...Please do read the user manual carefully and thoroughtly so as to ensure the safe usage of this product and keep the manual well for further reference in case you have problems Arm Type Contains FCC I...

Page 2: ...the Records Delete the Records Data Transmission INFORMATION FOR USER 15 Tips for measurement Maintenance ABOUT BLOOD PRESSURE 17 What are systolic pressure and diastolic pressure What is the standar...

Page 3: ...acemaker or defibrillator 2 The device is not intended to be a diagnostic device Contract your physician if hypertensive values are indicated Measurement Principle This product uses the Oscillometric...

Page 4: ...continuous monitoring during medical emergencies or operations Otherwise the patient s arm and fingers will become anaesthetic swollen and even purple due to a lack of blood Please use the device und...

Page 5: ...ttery door List 1 Blood Pressure Monitor 3 4 AAA batteries 6 2 Cuff Type BF applied part 22cm 32cm Please use iChoice authorized cuff The size of the actual cuff please refer to the label on the attac...

Page 6: ...ss Query button to change the numeral Each press 4 Repeat steps 2 and 3 to confirm the MINUTE Then the monitor diverts to MONTH and DAY setting MONTH DAY 5 Repeat steps 2 and 3 to confirm MONTH and DA...

Page 7: ...cuff s air pipe into the interface located on the right side of the monitor 2 As pictured on the right wear the cuff on your upper arm 3 Tighten the cuff up Make sure the cuff is fixed 2 to 3 centime...

Page 8: ...ther user button to switch to display another user s measurement data 4 When User 2 has no record the LCD will display just like the picture on the right 5 Press User 1 User 2 button to turn off the m...

Page 9: ...device 3 If the data transmission fails the symbol will remain The pending measurement data will be transmitted to your mobile device when next measurement is complete Within 1 hour after dinner or dr...

Page 10: ...uideline for Upper Limit of Normal BP Systolic Blood Pressure 135 mm Hg Diastolic Blood Pressure 85 mm Hg Irregular Heartbeat Detector An irregular heartbeat is detected when a heartbeat rhythm varies...

Page 11: ...breaths before beginning will be better for measuring Advice Relax yourself for 4 5 minutes until you calm down It is ok for both arms but there will be some different results for different people We...

Page 12: ...ad Haidian District 100143 Beijing P R China Complied Standards List 21 Risk Management ISO 14971 2007 Labeling EN 980 2008 User Manual EN 1041 2008 Generl Requirements for Safety IEC 60601 1 2005 A1...

Page 13: ...electronic equipment may be affected RF emissions CISPR 11 Class B Harmonic emissions IEC 61000 3 2 Not applicable Voltage fluctuations flicker emissions IEC 61000 3 3 Not applicable Guidance and manu...

Page 14: ...d below The customer or the user of the device should assure that it is used in such an environment IMMUNITY test IEC 60601 TEST LEVEL Complia nce level Electromagnetic environment guidance Conducted...