458DUO
Dual Balance Charger/Discharger/DC Power
- 31 -
Select the test mode and go to the following
corresponding
interface.
速度测试:
1.
Type:
Analog servo (1500us/50Hz)
Digital servo (1500us/333Hz)
Digital servo (760us/560Hz)
User: Pulse Center: 700us-1600us
Frame Rate: 40Hz-700Hz
45°Pulse Traveling:100us-1000us
2
. Liner Test
3
. Fixed point Test
4
. Speed Test
5
. Auto CW/CCW Test
Liner Test:
When turning the knob,
the pointer deflects with the setting
value of
Step,
and the servo responds
accordingly.
Fixed Point Test:
When turning the
knob, the pointer deflects among
each setting value and the servo
responds accordingly.
Auto CW/CCW Test:
Click
Test
button then the pointer deflects the
setting times at a set rate back and forth
among each setting values, and the
servo responds accordingly.
1
:
Channel
:
Channel 1(CH-1)
通道
1
Channel 1(CH-2)
通道
2
2
:
Output Voltage
4V-10V; default: 4.8V
3
:
Current Limit
1A-10A; default: 5A
4
:
Wiring diagram
1
2
3
4