456DUO
Dual Balance Charger/Discharger/DC Power
- 18 -
The value of
Balance Done Delay
is larger; the battery is closer to the setting cut-off voltage when the program ends.
Switch to
Balance charge mode
on
Chg Mode
, and click "
Set…
" behind
Chg End Current
to enter
CHARGE BALANCE
End SETUP
interface for setting.
LiPo/LiIo/LiFe/LiHV/LTO/NiZn/User Charge Advanced Setup
Click "
Advanc
e" to enter LiPo/LiIo/LiFe
ADVANCED SETUP
, after setting, click "
Back"
to return to the previous
interface.
1. When charging the over-discharged battery, the charger will detect if the cell voltage is larger than the restore voltage,
if larger, it will pre-charge the battery with restore current, if within the setting restore time, the cell voltage rises to the
normal value then it will turn to the charging program; otherwise it will stop running.
2. After charging, the battery may not be completely charged; tick "
Keep charging after the done
" to charge the battery
with smaller current when charging ends.
LiPo/LiIo/LiFe/LiHV/LTO/NiZn/User Safety Setup
Click "
Safety
" to enter
CHARGE SAFETY SETUP
.
Cut-Temp.
is the maximum safety temperature of the battery. If the external temperature sensor detects the set value, the
program will stop running in order to protect the battery from being damaged by high temperature.
LiPo/LiIo/LiFe/LiHV/LTO/User Storage Setup
This mode is for storing LiPo/LiIo/LiFe battery that will not to be used for an extended period. The charger determines
whether to charge or discharge the battery based on the configured target voltage. If the battery voltage exceeds the target
storage voltage it will start to discharge, while lower than the target storage voltage it will start to charge.
Select
Program
→
Storage
to enter
Storage
setup interface.
Cut-Temp:
20℃-80℃; default: 45℃
Max Capacity:
50%-200%; default: 120%
Safety Timer:
1Min-9999Min; default: off
1
2
3
4
1. The charger will stop balance charge if detects the
Balance condition is met, and the End Current
condition is invalid
2. The charger will stop balance charge if detects the End
Current condition is met, and the Balance condition is
invalid
3. The charger will stop balance charge if detects the End
Current condition or the Balance condition is met
4. The charger will stop balance charge if detects the End
Current condition and the Balance condition are
met
Restore Lowest Voltage:
0.5V/Cell-2.5V/Cell; Default: 1V/Cell
Restore Charge Time:
1Min-5Min; default: 3Min
Restore Charge Current:
0.02A-0.5A; default: 0.1A