406DUO V1.2.0
Synchronous Balance Charger/Discharger
- 22 -
NiMH/NiCd Battery Charge Advanced Setup
Click "
" to enter
NiMH/NiCd CHARGE OPTION SETUP
interface, after setting click "
" to return to the
previous interface.
Note: For the over-discharged NiMH/NiCd battery, the voltage may be close to 0V, tick
Allow 0V
Charging
to allow charge with 0V.
Tick
Trickle Enable
→
Enable
to activate trickle charge and set the parameters, after setting click"
" to return to the
previous interface.
Note: Tick
Enable
to activate trickle charge.
Trickle charge means when the standard charge is completed, the charger will charge the
battery with the setting trickle current until the setting trickle timeout, then to stop the
charging process.
NiMH/NiCd Battery Charge Safety Setup
Click "
" to enter
CHARGE SAFETY SETU
interface, see details about setting on Page19 LiPo/LiIo/LiFe Battery
NiMH/NiCd Battery Discharge Setup
Select
Program
→
Discharge
to enter
Discharge
setup interface.
Note: 1. Regenerative mode has three modes available
: OFF, To input, To channel. S
ee more details on
Page38
2
.To channel
Setup please see Page20
NiMH/NiCd Battery Discharge Safety Setup
Click "
" to enter
DISCHARGE SAFETY SETUP
interface, see details about setting on Page20
Battery Discharge Safety Setup
Sensitivity:
1mV-20mV; default: 3mV
Delay time:
0Min-20Min; default: 3Min
Trickle current:
0.02A-1A; default: 0.05A
Trickle timeout:
1Min-999Min; default: 5Min
Discharge Current:
0.05A-40A; default: 2A
Discharge Voltage
:
0.1V-35V; default: 0.1V
End Current:
1%-100%; default: 50%
Regenerative Mode
:
OFF (default), To input, To channel