406DUO V1.2.0
Synchronous Balance Charger/Discharger
- 20 -
Note: 1. The charger first discharges with constant current (CC) according to the user setting then turns
to constant voltage (CV) when it reaches the discharge voltage. In the CV phase the current
gradually falls, and the charger will terminate discharging when the current falls below the
percentage of the configured discharge current.
2. Regenerative mode has three available settings
: OFF, To input, To channel
, see more details on
Page38
To Channel Setup
When selecting to
To channel
on
Regenerative Mode
, “
"button changes from inactive to its operational status,
and click to enter
To channel
setup interface,
after setting click "
" to return to the previous interface.
Note: 1. For example, a 12V/60W bulb as the load of To Channel, it should set Voltage Limit =12V
;
Current Limit=60/12=5A.
2. When the battery as the load of To Channel, Voltage Limit and Current Limit are not settable
,
see details on Page38
LiPo/LiIo/LiFe Battery Discharge Advanced Setup
Click "
" to enter
LiPo/LiIo/LiFe DISCHARGE ADVANCED SETUP
interface, after setting click"
" to
return to the previous interface.
Note: 1. Tick
Extra Discharge Enable
to activate
discharge enable
, see more details on
Page39
2. Tick
Balance Enable
to activate
balance discharge
; when discharge enters the CV phase, it
starts to balance the cell voltages.
LiPo/LiIo/LiFe Battery Discharge Safety Setup.
Click "
" to enter
DISCHARGE SAFETY SETUP
, after setting click"
" to return to the previous interface.
Channel Join:
Resistance or bulbs (default)
Charging battery
Voltage Limit:
0.1V-40V; default: 12V
Current Limit:
0.05A-40A; default: 1A
Cut-Temp
:
20
℃
-80
℃
; default: 45
℃
Max Capacity:
50%-200%; default: 90%
Safety Timer:
1Min-9999Min; default: off