406DUO V1.2.0
Synchronous Balance Charger/Discharger
- 18 -
When switch to
User
Balance
mode on
Chg Mode;
the
Balance Diff, Balance Set Point, Balance Over Charge
and
Balance Done Delay
are available, after setting, click"
" to return to the previous interface.
Note: If
Balance Diff
value is lower, the voltage difference between individual cells will be lower and
the balancing will take more time before the program ends. If
Balance Set Point
value is lower,
the battery will be closer to the setting cut-off voltage and the time taken will be longer before
the program ends.
Balance Over Charge
, the maximum overcharge compensation voltage acts as
accelerated charge, and the larger the value, the more obvious the accelerated charge.
For example: Charge Lipo with Vstd, set
Balance Over charge
to Vboc, the cell’s internal
Resistance detected is Ri, when the charge current is Ia, the actual CV value of cells is Va
IF Ri*Ia > Vboc THEN
Va = Vstd + Vboc
ELSE
Va = Vstd+Ri*Ia
Please set this parameter after understanding fully, or keep the default value at 0.
The value of
Balance Done Delay
is larger; the battery is closer to the setting cut-off voltage
when the program ends.
Switch to
Balance charge mode
on
Chg Mode
, and click “
” behind
Chg End Current
to enter
CHARGE
BALANCE End SETUP
interface for setting.
LiPo/LiIo/LiFe Battery Charge Advanced Setup
Click "
" to enter
LiPo/LiIo/LiFe ADVANCED SETUP
, after setting, click"
"to return to the previous
interface.
Balance Diff:
1mV-10mV; default:5mV
Balance Set Point:
1mV-50mV; default:5mV
Balance Over Charge:
0mV-50mV; default:0mV
Balance Done Delay:
0Min-20Min; default:1Min
Balance Diff:
1mV-10mV; default:5mV
Balance Set Point:
1mV-50mV; default:5mV
Balance Over Charge:
0mV-50mV; default:0mV
Balance Done Delay:
0Min-20Min; default:1Min
1
2
3
4
1: The charger will stop balance charge if detects the
Balance condition is met, and the End Current
condition is invalid
2: The charger will stop balance charge if detects the End
Current condition is met, and the Balance condition is
invalid
3: The charger will stop balance charge if detects the End
Current condition or the Balance condition is met
4: The charger will stop balance charge if detects the End
Current condition and the Balance condition are met
Restore Lowest Voltage:
0.5V/Cell-2.5V/Cell; Default: 1V/Cell
Restore Charge Time:
1Min-5Min; default: 3Min
Restore Charge Current:
0.02A-0.5A; default: 0.1A