-19-
iCharger Synchronous Balance Charger/Discharger 3010B
Charge-to-discharge & Discharge-to-charge cycle mode for a Lithium battery
Lithium battery in monitoring mode
When you use other devices to charge or discharge Lithium pack, the
iCharger
can monitor each cell‘s
voltage, battery temperature, charge time and so on, if one of the batteries appears over-charged,
over-discharged, over-hot, over-capacity or over-time ,the
iCharger
will alarm with noise
“Di…..”
and blink
the raleted information.
Note
: when in Li monitor Mode, no need connecting the main port if connecting the balance port.
Charging/discharging cycle mode of Lithium battery.
The left side of the first line sets the type of battery (LiPo, Lilo or LiFe) and
the right side shows the cycle number. The second line shows the cycle
direction you selected: (C: x.xxV->D: x.xxV) or (D: x.xxV->C: x.xxV), the
value of the second line sets the final charge/discharge voltage. Press
Start/Enter
button for more than 3 seconds with a sound ‖Di‖ to start the
next process.
Cycle number: 1
–
999
(only last 10 times cycle information will be
displayed)
Voltage: LiPo (3.00
–
4.20V), Lilo (2.50
–
4.10V), LiFe (2.00
–
3.60V)
The number of cells you set and the processor detects. If the checking
result is the same, it would enter to the next interface; if not the same, the
left side of the first line ‘R: xxSER‘ shows the number of cells detected by
the
iCharger
and the right side of the first line ‘S:xxSER‘ is the number of
cells set by the user. You should make sure that the configured number and
the actual number for the battery are the same and then you can start
charging by pressing
Start/Enter
. If not, press
Batt type/Stop
to go back to
the previous screen and adjust the setting.
Charging/discharging cycle mode of Lithium battery.
In this process, you can stop the cycle at any time by pressing the
Batt
type/Stop
button. In the process of C>D or D>C, the blink ―C‖ indicates
charging, while ―D‖ indicates discharging. Press
Inc
button to display
each cell‘s voltage and its past cycling current (see the balance voltage
information& cycling information) and press
Dec
button to display the
General Status information.
During the waiting time of discharge-to-charge cycle mode, you can stop
the waiting process with pressing ―Start" button for three seconds!
LiPo MONITOR
3.0V 11.1V(3S)
Monitor mode of Lithium battery. The left side of the first line sets the type of
battery (LiPo, Lilo or LiFe). The value on the right side of the second line
sets the low limit of voltage and the battery pack number. After setting the
current and voltage press
Start/Enter
button for more than 3 seconds with
a sound ‖Di‖ to start the next process.
Individual alarm low-Vt: final discharging voltage to the highest
charging voltage (such as: LiPo 3.0V
–
4.2V),
Battery series: 1
–
10 series
The monitor information, in this process; you can stop monitoring process at
any time by pressing
Batt type/Stop
button
.
Press
Inc
button to display each cell‘s voltage (see the balance voltage
information), the
iCharger
will alarm with noise
“Di….”
when any errors
appear.
Start/Enter
>3 seconds
Batt type
stop
R:02SER S:03SER
CONFIRM(ENTER)
Start/Enter
Batt type
stop
Battery
Series
V-BP
Charge
Current
Li03 1.0A 12.60V
C>D 00993 59m:51
battery
voltage
number
of cells
Series
cycle
capacity
cycle
time
cycle
current
work
state
Start/Enter
>3 seconds
Batt type
stop
Battery
Series
V-BP
Charge
Current
Li03 50℃ 12.60V
Monitor 50m:43
battery
voltage
number
of cells
Series
run
time
Ext.
temperature
work
state
LiPo CYCLE 3
C:4.20V->D:3.00V
-
Dec
+
Inc
-
Dec
+
Inc
-
Dec
+
Inc
-
Dec
+
Inc
-
Dec
+
Inc
-
Dec
+
Inc