Use a sanitizier to remove algae or sticky substances (sodium hypochlorite or equals to)
Do not use a Sanitizer to remove calcic substances or other minerals.
1. When the deicing cycle has been completed and the ice has been
fallen off from the Assembly Evaporator, turn off the main switch.
2. Remove ice from the inner case, and close the water supply valve.
5. The Sanitizing Procedure will take about 10 minutes.
8. Reassemble the Sanitized components and parts.
10. Conduct the second Sanitizing Procedure.
6. After 10 minutes, turn the main switch to OFF position.
3. Put 0.013gal (50
m ℓ
) of a Sanitizer into vessel sheet. (Approximately 5% of the volume
(0.264gal (1
ℓ
) ) of the vessel sheet).
7. The ice damper assembly and ice scoop which can be disassembled should be removed
and sanitizier with 0.264gal (1
ℓ
) of sanitizier diluted in 5.4gal (20
ℓ
) of water.
4. To start the first Sanitizing Procedure, set the main switch to “WASH” position.
The pump motor will repeat 5 cycles of running for about 90 seconds and being stopped
for 30 seconds.
9. When the first Sanitizing Procedure has been completed, remove the packing down
from the inner vessel sheet downwards, remove the water inside the packing down
and insert it back into the vessel sheet.
11. Open the water supply valve to pour water into the vessel sheet.
Put 0.013gal (50
m ℓ
) of Sanitizer into the water. Close the water supply valve.
Set the main switch to “WASH” position to Sanitization.
Never apply force to the Assembly Evaporator (it may be broken).
ice damper
scoop
Sanitizing Procedure
packing down
ice damper
ICE
OFF
WASH