iCentral Multicom Classic Installation Manual
P a g e
|
24
Auto Opening
You can use the internal time clock feature to hold open gates
at pre-set times and days of the week. For gates that are on
step by step operation, set trigger times to activate opening
and closing. For auto-closing gates, set LATCH times to open,
and then set separate UNLATCH times to close again. Up to
9 SMS event messages can be sent in total.
Toggle between trigger, latch and unlatch
SMS Strings
Delete all automatic relay events
5555
#
*
#
Enter time in 24hr format, no colon. Eg
8.20am = 0820. 11.40pm = 2340.
Add Auto opening / closing times
5555
#
X
#
day,day,day,day
#
time
#
Manager Pass code
1
= Relay 1 trigger
2
= Relay 1 latch
3
= Relay 1 unlatch
4
= Relay 2 trigger
5
= Relay 2 latch
6
= Relay 2 unlatch
Add days, 3 digits, e.g.
mon,tue,wed,thu,fri,sat,sun.
Separated by comma.
Time in 24hr format. No
colon. E.g. 11.15pm = 2315