INITIAL CONNECTIONS

Unplug your Maxspect Gyre Pump’s power supply. Remove the standard Gyre controller 

and re-connect the pump and power supply cable to Gyre Interface Module. Plug one 

end of the included module Y cable into the side of the Gyre Interface Module and the 

opposite end  with the ethernet connection into an available 0-10v port on your existing 

system controller. 

OPERATIONAL MODE

In operational mode the Status light should always be turned off. If the controller detects 

an error, such as a blocked rotor or no pump present, the status light will illuminate red 

and the pump will be stopped. The red light will generally remain on for 1-2 seconds, then 

it will turn off and the controller will try to restart the pump. If the error condition is gone, 

the pump will continue to run. If it detects the error once more, the red light will turn on 

again. The result of this is that a persistent error condition 

(such as a missing pump)

 re-

sults in a very slowly blinking red light where it is on for about 2 seconds and off for about 

2 seconds 

(depending on the error condition)

.