Working with Master/Slave
8-25
ICE Vulcan Service Manual
The Slave LPAs
In Group Job Select mode only the JOB button on the home screen of CLARiTY is disabled, as
job selection can only be initiated from the Master LPA, as shown in Figure 8-23.
Disabled Job Button
Figure 8-23: CLARiTY Home page
Note:
Standard LPAs in Slave mode and Slave LPAs (No CLARiTY LCD) accepts
communications from CLARiTY Configuration Manager and other software packages, e.g.
CLARiSOFT.
Using Master/Slave Mode - Group Control Mode
Group Control mode allows Slave LPAs to be controlled from the Master LPA CLARiTY interface.
In addition to the parameters available in Group Job Select mode, additional Setup and
Diagnostics CLARiTY pages are available for setup and diagnostics information.
The Master LPA
In Group Control mode, the CLARiTY Operator interface acts differently to that of a standalone
LPA.
Using only the screen of the Master LPA it is possible to view Diagnostic and edit Set Up
information on the Master and any chosen Slave LPA, as shown in the example below.
Summary of Contents for vulcan
Page 1: ...ICEVulcanServiceManual Vulcan Service Manual ...
Page 20: ...Equipment Safety Guidelines 2 5 ICEVulcan ServiceManual manual ...
Page 33: ...Labeller 3 8 ICEVulcan ServiceManual Figure 3 9 Dancer Arm Sensor PCB ...
Page 60: ...Installing the Label Applicator 4 13 ICEVulcan ServiceManual place Use an adjustable wrench ...
Page 168: ...Rev AA Printhead Assembly 7 20 ICEVulcan ServiceManual Table 7 31 Printhead Cable Guide ...
Page 173: ...Rev AA Printhead Assembly 7 23 ICEVulcan ServiceManual Table 7 39 Ribbon Drive Motor ...
Page 235: ...C 2 Main Board Test Points Rev AA ...