The Ball Gate Assembly:  Technical Information

 

Two half

-

moons attached together and connected to a single motor.  The position of the left half

-

moon is 

sensed by two reed switches.  A small magnet is located under the left moon.  When the reed switch is      
activated, it will be at 0 VDC, the other will be opposite, +5 VDC.

 

 

On the main board at J14, pins 1 and 2 supply the voltage to the ball gate motor.  Pins 3 and 4 are the sense 
lines used to determine the position of the ball gate.  Located underneath the left side of the ball gate is a 
magnet.  When the gate is closed this magnet activates the sensor attached to pin 3 taking the signal to 
ground.  Pin 4 will be at +5 VDC.  When the gate opens, pin 4 will go to ground and pin 3 will have +5 VDC on 
it.

 

 

If the magnet sensors are not flush to the wood surface, the magnet will not activate the sensor causing the 
ball gate to move pass the closed or open position.  When this occurs, the ball gate will shut down and only a 
power cycle will allow the ball gate to work again.

 

 

If after checking that the ball gate is not having a sensor problem, look at the linkage for any of the Grubb 
screws that might have gotten loose.  Also look at the connector rod and make sure it is slotted and not 
rounded out. 

 

 

** Note ** 

If the game doesn

t see the open or close reed switches it will open the ball gate and not 

attempt to run the ball gate motor again until you power cycle the game.  

 

Reed switch embeds into the wood instead of being at the surface.

 

Summary of Contents for SNOWBALL TOSS

Page 1: ...1 ...

Page 2: ...ngs and Power Requirements 3 Game Controls and Meters 4 Automatic Game Settings Program Options 5 Recommended Bonus Values 7 Error Codes 8 Troubleshooting and Technical Information The Ball gate Assembly 9 Warranty 11 Rev A 11 12 2019 ...

Page 3: ...OT remove any of the components on the main board e g compact flash and eproms while the game is powered on This may cause permanent damage to the parts and the main board Re moving any main board component part while powered on will void the warranty ALWAYS REMOVE POWER TO THE GAME BEFORE ATTEMPTING ANY SERVICE UNLESS NEEDED FOR SPECIFIC TESTING FAILURE TO OBSERVE THIS PRECAUTION COULD RESULT IN ...

Page 4: ...P and DOWN push buttons You can view how many coin pulses and tickets has been paid by viewing the meters Automatic Game Settings You can use the game s automatic game setting feature if you know your price of play When you power the game on wait until the version number is displayed on the control panel Press the SELECT button 99 will be shown on the score display to indicate you are in this mode...

Page 5: ...econds between Red lite Attempts During the game you can determine how much time to wait before lighting a clown red for the double point feature 7 Bonus Score 500 10 999 10 Bonus Target Score How much a player must score before achieving the bonus cloud 8 Bonus Tickets 100 0 999 25 Bonus Ticket Value How many tickets you win when you win the bonus cloud 9 Game Time 20 10 30 1 Time for Game Play H...

Page 6: ...core chart below 17 Score 450 Bonus 10 1 250 1 Tickets for Zone Sets the amount of tickets to win when 400 490 points are scored See Score chart below 18 Ticket Multiplier 1 0 2 1 0 Just for Fun 1 1 ticket 1 ticket 2 2 tickets 1 ticket This allows you to either turn off tickets and play for a score pay out normal or pay 1 2 the amount of tickets owed 19 Game ID 0 0 2 1 0 No marquee used When two g...

Page 7: ...7 ...

Page 8: ...ate operation See section Ball Gate Assembly Error 4 Ball Gate Open Error Game didn t see the sensor for open Solution Check for proper ball gate operation See section Ball Gate Assembly Error 5 Top Motor Switch Error Top Row switch not seen Solution Check Clown Reset Bracket sensor Error 6 Bottom Motor Switch Error Bottom Row switch not seen Solution Check Clown Reset Bracket sensor To enter Erro...

Page 9: ... ground Pin 4 will be at 5 VDC When the gate opens pin 4 will go to ground and pin 3 will have 5 VDC on it If the magnet sensors are not flush to the wood surface the magnet will not activate the sensor causing the ball gate to move pass the closed or open position When this occurs the ball gate will shut down and only a power cycle will allow the ball gate to work again If after checking that the...

Page 10: ...nt When the magnet is not over the sensor it should read 5 volt of DC power With the power off on the game the sensor is normally open WARNING Never manually move the Primary Ball Gate assembly as damage will occur to the motor gearbox assembly below Ball gate sensors Access Remove the two screws that hold the gate cam to the Primary Ball gate assembly Slide the Primary Ball gate assembly out Gate...

Page 11: ...r fault symptoms I C E Inc will assume no liability whatsoever for costs associated with labor or travel time to replace defective parts All defective warranty covered components will be replaced with new or factory refurbished compo nents equal to OEM specifications I C E Inc will cover domestic UPS ground or comparable shipping costs during the warranty period Interna tional or expedited shipmen...

Reviews: