ENGLISH
10
7. WATER LEVEL
The function of the water level is to maintain the necessary flow on the evaporator, and using the magnetic
micro device incorporated, stop the operation of the machine until the water reaches again the container.
The models 400, 550 and 1100 have a water pressostat replacing the micro-magnetic.
The optimum level is located on the horizontal indicated in the figure, and its regulation is made following
the indications appearing below.
START-UP
1. Previous Checkup
a) Is the machine leveled?
b) Voltage and frequency are the same as those on the nameplate?
c) Are the discharges connected and operating?
d) ** If air condensed: Is the air circulation and its temperature appropriate?
e) ** Is water pressure appropriate?
NOTE:
In case input water pressure is higher that 6 Bar (85 psi), install a pressure reducer. THE BIBB
CONNECTION PRESSURE SHOULD NEVER BE REDUCED.
FLOAT VALVE REGULATION
FLOAT
PROBE
SAFETY OVERFILL
Turn upwards to increase the level,
and downwards to decrease it.
(Grab from the metallic arm, NEVER
FROM THE FLOAT)
ROOM
WATER
MAXIMUM
43ºC / 109,40ºF
35ºC / 95ºF
MINIMUM
5ºC / 41ºF
5ºC / 41ºF
MINIMUM
0,7 Bar (10 psi)
MAXIMUM
6 Bar (85 psi)