ICE AIR RSAN Operating & Maintenance Manual Download Page 9

9

OPERATING & MAINTENANCE MANUAL

 

 

PACKAGED TERMINAL AIR CONDITIONER (PTAC) – RSAN

EVENT TIME

HEAT

COOL

MON-

FRI

WAKE
LEAVE
RETURN
SLEEP

6:00 AM
8:00 AM 
6:00 PM 
10:00 PM

70º F (21º C) 
62º F (17º C) 
70º F (21º C) 
62º F (17º C)

78º F (26º C)
85º F (29.5º C) 
78º F (26º C) 
82º F (28º C)  

SAT-

SUN

WAKE
LEAVE
RETURN
SLEEP

6:00 AM
10:00 AM 
6:00 PM 
11:00 PM

70º F (21º C) 
62º F (17º C) 
70º F (21º C) 
62º F (17º C)

78º F (28º C)
85º F (29.5º C) 
78º F (26º C) 
82º F (28º C)  

Below is the default program: 

The default selection is 5-2 day program. 

Changing Program Schedule and Temperature Limits 

Press [On/Off] twice to select Settings  

(Settings is flashing)

1.  Press [Mode] key to select Edit “Settings.”

2.  Use [Up] and [Down] to select 7 Day or 5-2 

Day.

3.  Press [Mode] to edit Heat Temperature Limit.

4.  Use [Up] and [Down] to set temperature. 

Default internal setting: Heat limit 90°F

5.  Press [Mode] to edit Cool Temperature Limit.

6.  Use [Up] and [Down] to set temperature. 

Default internal setting: Cool limit 60°F

7.  Press [Fan] when complete. 

The cool limit setting should be at least 4°F 

higher than the heat limit setting.

• 

The cool limit setting is 55°F to 95°F

• 

The heat limit setting is 51°F to 91°F

 

Exit Internal Setting and Return to Normal Mode

1.  Press [Fan] to confirm and return to normal mode

2.  If no key is pressed for 15 seconds, it will return to 

normal mode automatically

Temporary Program Override

1.  When thermostat is ON, the program set-point can 

be temporarily overrode by pressing [UP] or [DOWN].  

“OVERRIDE” icon will turn on.  Press[UP] or [Down] 

to select the set-point

2.  In Heat mode, Heat set-point can be adjusted

3.  In Cool mode, Cool set-point can be adjusted

4.  In Auto mode, Heat set-point will be set first and 

press [UP] or [DOWN] to set the Heat set-point. 

Press [Fan] to confirm the Heat set point. Cool set-

point will be set second and press [UP] or [DOWN] 

to set the Cool set-point. Press [Fan] to confirm the 

Cool set-point.

5.  Temporary Override will be cancelled if user  

changes the operation mode or the unit enters  

the next program time session. 

Permanent Override 

1.  Holding [UP] and [Down] key for 2 seconds to enter 

Permanent Override mode.  

Permanent Override icon will turn on.

2.  In Heat mode, Heat set-point can be adjusted.

3.  In Cool mode, Cool set-point can be adjusted.

4.  In Auto mode, Heat set-point will be set first and 

press [UP] or [DOWN] to set the Heat set-point. 

Press [Fan] to confirm the Heat set-point. Cool set-

point will be set second and press [UP] or [DOWN] to 

set the Cool set-point. 

5.  Permanent Override will be cancelled if user  

changes the operation mode or turns off the unit.

6.  Hold [Fan] key 5 seconds to cancel the permanent 

override mode. 

Operating Specifications

• 

Temperature measurement 

 

°C ~ 40°C / 32°F ~ 99°F

• 

Accuracy: ±0.5°C/ 1°F

• 

Voltage: 18-30VAC

• 

Temperature Controllable range: 

 

5°C~35°C / 55°F ~ 95°F

• 

Resolution: 0.5°C /1°F

• 

Operating temperature: 

 

0 – 50 °C / 32 – 122 °F

• 

Storage temperature: 

 

5 – 50 °C/ 23 – 122 °F

Summary of Contents for RSAN

Page 1: ...Packaged Terminal Air Conditioner PTAC OPERATING MAINTENANCE MANUAL World Class Comfort Model RSAN ...

Page 2: ...Y OPERATION FOR SAFE AND OPTIMAL ENJOYMENT OF YOUR ICE AIR PTAC UNIT PLEASE READ THE FOLLOWING CONSUMER SAFETY AND OPERATING NOTES CAREFULLY BEFORE OPERATING YOUR EQUIPMENT This unit MUST be serviced only by professionally trained qualified technicians Do NOT attempt to maintain or service this unit on your own severe injury and death can occur from electric shock moving parts and other hazards Ou...

Page 3: ...ned or positioned so that the air discharge from the unit does not flow behind these window treatments Have the unit filter properly cleaned and serviced to prevent air blockage from dirt and dust within the filter media Proper installation and operating environment must be maintained Therefore Do not operate the unit in corrosive environments such as chemical plants refineries or salt spray areas...

Page 4: ...OPERATING MAINTENANCE MANUAL PACKAGED TERMINAL AIR CONDITIONER PTAC RSAN 4 RSAN EXPLODED VIEW ...

Page 5: ...5 OPERATING MAINTENANCE MANUAL PACKAGED TERMINAL AIR CONDITIONER PTAC RSAN DIMENSIONAL DRAWING ...

Page 6: ...ture set point is reached Fan Speed Press the FAN button to select high medium or low fan speed Operating Modes Press the MODE button to select between Cooling Heating and Fan modes 3 OPERATING MODES Cooling Mode Under cooling mode the user can select a specific fan speed and temperature set point Heating Mode Under heating mode the user can select a specific fan speed and temperature set point Fa...

Page 7: ...w Temperature Protection USER INTERFACE DESCRIPTION TROUBLESHOOTING E4 LOW REFRIGERANT CHARGE Low charge dirty filter or dirty evaporator coil E6 SYSTEM HIGH PRESSURE PROTECTION Condenser fan failure dirty condenser coil or capillary tube blockage E8 INDOOR COIL FREEZE PROTECTION Dirty filter dirty evaporator coil or fan motor failure E9 COMMUNICATION ERROR Faulty wiring from touchpad to board or ...

Page 8: ...ure Auto Mode To activate auto mode press the mode button until AUTO displays Press up down arrow keys to set desired heat temperature Wait 5 seconds for cool to appear Press up down arrow keys to set desired cool temperature The unit will automatically cycle between heat and cool modes if unit exceeds desired set points The temperature reading that is on constant display is the ambient room tempe...

Page 9: ...orary Program Override 1 When thermostat is ON the program set point can be temporarily overrode by pressing UP or DOWN OVERRIDE icon will turn on Press UP or Down to select the set point 2 In Heat mode Heat set point can be adjusted 3 In Cool mode Cool set point can be adjusted 4 In Auto mode Heat set point will be set first and press UP or DOWN to set the Heat set point Press Fan to confirm the ...

Page 10: ...hoses annually to ensure proper condensate drainage If any foreign matter build up in the drain pan is found clean the drain pan and drain hoses frequency of cleaning depends on the level of dirt and pollutants that may be present in the indoor environment Check and clean if necessary the unit evaporator coil annually Check unit line cord power connection for any fraying or deterioration of the pl...

Page 11: ...sive noise and vibration from this assembly it should be serviced by a qualified technician ROOMSIDE COMPONENT CLEANING EVAPORATOR COIL AND DRAIN PAN DRAIN HOSES IMPORTANT NOTE In addition to the air filter the roomside components can be cleaned without removing the PTAC chassis from the wall sleeve The power cord MUST be disconnected from the electrical outlet before carrying out any of the follo...

Page 12: ...UALIFIED TRAINED PERSONNEL ELECTRIC SHOCK HAZARD DISCONNECT FROM LIVE ELECTRIC CIRCUIT BEFORE SERVICING MOVING PARTS HAZARD DISCONNECT FROM LIVE ELECTRIC CIRCUIT BEFORE SERVICING UNIT MUST BE OPERATED WITH ALL CHASSIS SHEET METAL PARTS PROPERLY IN PLACE UNIT MUST BE OPERATED WITH ALL ENCLOSURE CABINET PARTS IN PLACE READ THIS ENTIRE OPERATIONS MANUAL BEFORE OPERATING THE UNIT DO NOT OPERATE UNIT W...

Reviews: