Precautions and preparations listed are for general knowledge and to define basic guidelines. Local codes and existing practices should be observed and preformed by a professional. 

Due to ICE AIRs ongoing product development programs, the information in this document is subject to change without notice.

Item 1

8

Voltage

5

- 115V - 1Ph - 60Hz   

8

- 208V - 1Ph - 60Hz   

7

- 277V - 1Ph - 60Hz

Item 2

FCHC

Unit

FCHC

Item 3

08

CFM

02

- 200   

03

- 300   

04

- 400   

06

- 600   

08

- 800   

10

- 1000   

12

- 1200

Item 4

E

Motors

P

- PSC   

S

- PSC Hi Static   

E

- ECM

Item 5

M

Piping

A

- RH 2 Pipe Heat and Cool MCO   

B

- RH 2 Pipe Heat and Cool w/Aux Electric Heat MCO   

C

- RH 2 Pipe Heat and Cool w/Aux Electric Heat ACO   

D

- RH 2 Pipe Cool w/Total Elec Heat MCO   

E

- RH 2 Pipe Cool w/Total Elec Heat ACO   

F

- RH 2 Pipe Heat Only   

G

- LH 2 Pipe Heat and Cool MCO   

H

- LH 2 Pipe Heat and Cool w/Aux Electric Heat MCO   

I

- LH 2 Pipe Heat and Cool w/Aux Electric Heat ACO   

J

- LH 2 Pipe Cool w/Total Elec Heat MCO   

K

- LH 2 Pipe Cool w/Total Elec Heat ACO   

L

- LH 2 Pipe Heat Only   

M

- RH 4 Pipe Heat and Cool MCO   

N

- RH 4 Pipe Heat and Cool ACO   

O

- LH 4 Pipe Heat and Cool MCO   

P

- LH 4 Pipe Heat and Cool ACO

Item 6

X

Enclosure

X

- Not applicable

Item 7

X

Plenums

B

- Bottom Return   

R

- Rear Return   

F

- Front Return   

X

- No Plenum

Item 8

6

Controls

1

- Unit Mounted Fan Mode Switch   

2

- Wall Mounted Fan Mode Switch   

3

- Unit Mounted Fan Mode Switch and Manual (Knob) Thermostat   

4

- Touchpad non programmable thermostat   

5

- LCD Non programmable thermostat   

6

- LCD programmable thermostat   

7

- Wired for ELA11599 Non Programmable Thermostat   

8

- Wired for ELA11599 Programmable Thermostat   

9

- 24V Terminal for external controls by others

Item 9

2

Coil Rows

2

- 2   

3

- 3   

4

- 4

Item 10

B

Coil Orientation

B

- 1 Cool, 1 Heat

Item 11

S

Drain Pan

G

- Galvanized Powder Coated (Black)   

S

- Stainless Steel

Item 12

X

Disconnect Switch

F

- Fused   

N

- Non Fused   

X

- None

FCHC Nomenclature

Model Selection

8

FCHC 08

-

E M X X 6 2 B S X -

1 A G A X 1 P P M F S

Item Number

1

2

3

4 5 6 7 8 9 10 11 12

13 14 15 16 17 18 19 20 21 22 23

Primary Part

Secondary Parts

Valve Package Parts

4

Summary of Contents for FCHC

Page 1: ...codes and existing practices should be observed and preformed by a professional Due to ICE AIRs ongoing product development programs the information in this document is subject to change without notic...

Page 2: ...ervice or service procedures If you install or perform service on this unit you assume responsibility for any personal injury or property damage which may result Many jurisdictions require a license t...

Page 3: ...ctions Units should be installed no closer than 18 apart when two units are side by side A vertical clearance of 60 should be maintained between units 2 Adequate ceiling panel access must exist for ha...

Page 4: ...l Elec Heat MCO K LH 2 Pipe Cool w Total Elec Heat ACO L LH 2 Pipe Heat Only M RH 4 Pipe Heat and Cool MCO N RH 4 Pipe Heat and Cool ACO O LH 4 Pipe Heat and Cool MCO P LH 4 Pipe Heat and Cool ACO Ite...

Page 5: ...e Item 16 A Flow Regulation Cooling Coil A Balancing Valve B Circuit Setter C Autoflow Valve 0 5 GPM D Autoflow Valve 1 0 GPM E Autoflow Valve 1 3 GPM F Autoflow Valve 1 5 GPM G Autoflow Valve 2 0 GPM...

Page 6: ...LH 2 Pipe Cool w Total Elec Heat ACO L LH 2 Pipe Heat Only M RH 4 Pipe Heat and Cool MCO N RH 4 Pipe Heat and Cool ACO O LH 4 Pipe Heat and Cool MCO P LH 4 Pipe Heat and Cool ACO Item 6 X Enclosure X...

Page 7: ...Way MV Normally Open Diverting 17 24V 3 Way MV Normally Closed Routing w Bypass Pipe 18 24V 3 Way MV Normally Closed Diverting w Bypass Pipe 19 24V 3 Way MV Normally Open Routing w Bypass Pipe 20 24V...

Page 8: ...ithout interference 7 A minimum obstructed distance of 36 should be kept around theunit IMPORTANT To avoid permanent damage to the unit DO NOT operate during construction in an open space or as a supp...

Page 9: ...n the unit Piping Installation ICE AIRs Horizontal Concealed Fan Coil is available in either 2 pipe or 4 pipe configurations see below that are connected to the system through the use of a flexible ho...

Page 10: ...2 Pipe System General Electric Line Voltage Wiring including the electrical ground must comply with the National Electrical Code as well as all applicable local codes Refer to the Electrical Data tab...

Page 11: ...n motor when present Component Outline Field Wiring Factory Wiring Wire Color Wire Connector Field Connector CLG HTG C SI V Legend BLK CAP Front 3 2 1 6 5 4 9 8 7 12 11 10 1 2 3 4 5 6 7 8 9 10 11 12 M...

Page 12: ...system with water leaving the air vents open Bleed all air from the system but do not allow the system to over flow Check the system for leaks and make any required repairs 4 Adjust the water and air...

Page 13: ...leshooting Table Troubleshooting IMPORTANT It is not the intent of this maintenance manual to resolve any problems with the operation of your ICE AIR unit Please contact a trained servicer or building...

Page 14: ...ation in Building Date Sales Order No In order to minimize troubleshooting and costly system failures complete the following checks and data entries before the system is put into full operation Temper...

Page 15: ...son including any agent salesman dealer or distributor has authority to expand ICE AIRs obligation beyond the terms of these express warranties or to state that the performance of the product is other...

Reviews: