EXCELPRIME
3
Owner’s Manual
STRAIGHT UP INSTALLATION
For most straight up installations the only
part required is an adjustable length
(SWA). The SWA adjusts to allow any
overall length from 40" to 68". The SWA
is packed in two pieces.
Pick up the section with the expanded top
and slide it into the section with the
shrunk bottom. Do not drop the length or
it may become stuck.
1. Set the adjustable length so that the
shrunk bottom fits into the flue collar of
the stove. Screw the pipe to the flue collar
with three 3/4” metal screws. The black
screws provided are self drilling and will
not normally need a pilot hole for steel
stove collars.
2. Slide the top length of the SWA up over the chimney pipe adapter at the
bottom of the chimney support. Connect it to the adapte
r with three 3/8’’
metal screws provided.
3. If the system is straight (i.e. no elbows), then it is not recommended to fasten
the slip joint in SWA to allow for expansion.
4. If you require additional height you may add lengths above or below the
adjustable length. Always install the shrunk end on the bottom. Screw two
lengths of EXCELPrime to
gether with the 3/8’’ metal screws provided.
90° ELBOW INSTALLATION
When connecting EXCELPrime to a chimney at the wall, there are multiple
choices for 90° elbows (SW90, SW90C, SW90S & SWA90).
SW90 - 90
°
elbow
SW90C - Clean Out Elbow
SW90S - Slip Elbow
SWA90 - Adjustable Elbow
SW90
SW90C
SW90S
SWA90
Most 90° elbow installations only require an elbow and the adjustable length
(SWA). If the height from the top of the stove to the top of the elbow is less
than 48”, then you will require a shorter length and a slip section or the slip
elbow. Depending on the wall construction you may also require a short length
between the wall and the elbow to ensure safe clearances.
sl
ip