INSTALLATION AND MAINTENANCE 

INSTRUCTIONS

 

 

  

 
A  MAJOR  CAUSE  OF  CHIMNEY  RELATED  FIRES  IS  FAILURE  TO  MAINTAIN 
REQUIRED CLEARANCES (AIR SPACE) TO COMBUSTIBLE MATERIALS. IT IS OF 
UTMOST  IMPORTANCE  THAT  THIS  CONNECTOR  BE  INSTALLED  ONLY  IN 
ACCORDANCE WITH THESE INSTRUCTIONS. 
 
 

Allowable Flue Gas Temperatures 
Maximum Continuous 

 

1200°F 

 

650°C 

 

Brief Forced Firing

 

1700°F 

 

925°C 

 

Tested To

 

2100°F 

 

1150°C 

 

 

 

EXCELPrime  is  used  to  connect  a  solid,  liquid  and  gas  fired  appliances, 
including wood burning stoves, freestanding fireplaces, and furnaces to a pre-
fabricated metal or masonry chimney. EXCELPrime is intended for interior use 
only. 

Contact  local  building  or  fire  officials  about  local  restrictions  and  building 
inspections in your area.  

Always follow the wood burning stove manufacturer's installation instructions.  

Keep these installation and operating instructions in a safe location  for future 
reference. 

 

EXCELPrime has been tested and listed by 
Intertek Testing Services as per Standard ULC-S641 
ETL Listing #4005717 

 

 
 

 

 