ICA CT Series User Manual Download Page 3

I. INTRODUCTION / 

 

PENDAHULUAN

1

UPS (Uninterruptible Power Supplies) can provide full 

protection against all of power problem for your sensitive 
equipment ranging from computer, computerized instrument, 
PABX, facsimile, cash register to all electronic equipment. 

This UPS consists of inverter, batteries, battery charger, control 

circuit, stabilizer, transfer switch and indicator. When line power is 
normal, the UPS filters line power input and by pass to output UPS 
and at the same time the batteries is being chargered by battery 
charger. And when line power fails (off, voltage too low), inverter 
will supply regulated AC power to the load within   4 ms transfer 
time so that the power supplied to the load is uninterrupted. And 
when line power is normal automatically load gets from line power 
again. 

This UPS is also completed by interface for communication 

with computer, with operating system Windows 95, 98, ME, Unix / 
Linux and Windows NT4/2000.  Information from UPS to 
Computer is 

 and 

<

power fail

battery low

UPS (Uninterruptible Power Supplies) dapat melindungi 

peralatan anda yang rentan terhadap gangguan kelistrikan seperti 
computer, instrument terkomputerisasi, 

, faksimili, cash 

register dan peralatan elektronik lainnya.

UPS ini dilengkapi interface untuk berkomunikasi dengan komputer, 
dengan sistem operasi Windows 95, 98, ME, Unix/Linux maupun 
Windows NT4/2000. Informasi yang diberikan kepada komputer 
adalah 

 dan 

 

.

PABX

<

listrik padam

baterai hampir habis

UPS ini terdiri atas inverter, baterai, pengisi baterai, rangkaian 

pengendali, stabilisator, saklar pengalih dan indikator. Saat listrik 
jala-jala normal, UPS menyaring listrik masukan dan 
menyalurkannya pada keluaran UPS, pada saat yang sama baterai 
diisi oleh pengisi baterai.  Manakala terjadi gangguan listrik (padam, 
tegangan terlalu rendah), inverter seketika bekerja dengan waktu 
alih   4ms sehingga pasokan listrik pada beban tidak terganggu / 
terputus. Dan bila listrik jala-jala pulih maka otomatis beban 
mendapat daya listrik jala-jala kembali.

AC INPUT

TO COMPUTER

UPS OUTPUT

TRANSFER

SWITCH

INVERTER

CHARGER

BATTERY

STABILIZER

&

INDICATOR

CONTROL CIRCUIT

Summary of Contents for CT Series

Page 1: ...UNINTERRUPTIBLE POWER SUPPLIES CT 382 B CT 682 B CT 1082 B CT 1382 B CT 1682 B CT SERIES ICA 481 1120090 171 Rev 03...

Page 2: ...EAR PANEL VIEW TAMPAK PANEL DEPAN PANEL BELAKANG 1 Page Halaman 2 3 IV V VI VII VIII IX SAFETY NOTES CATATAN KESELAMATAN INSTALLATION INSTALASI START UP UPS MENGHIDUPKAN UPS OPERATION PROCEDURE CARA M...

Page 3: ...om UPS to Computer is and power fail battery low UPS Uninterruptible Power Supplies dapat melindungi peralatan anda yang rentan terhadap gangguan kelistrikan seperti computer instrument terkomputerisa...

Page 4: ...Weight A C I N DC IN I N V O U T C H G Current Frequency Protection Internal Battery Protection Wave Form Voltage Frequency Power Efficiency Type Voltage Current 1 6 3 15 6 3 10 1x12V 7AH 2x12V 7AH 3x...

Page 5: ...FRONT PANEL REAR PANEL VIEW TAMPAK PANEL DEPAN PANEL BELAKANG 3 1 2 3 4 5 9 6 8 7 FRONT PANEL VIEW UPS CT382B CT682B CT1082B CT1382B CT1682B REAR PANEL VIEW UPS CT382B REAR PANEL VIEW UPS CT682B 9 5 6...

Page 6: ...Led hijau menunjukkan keluaran UPS berasal dari listrik jala jala Yellow led indicate output UPS from inverter Led kuning menunjukkan keluaran UPS berasal dari inverter For communication between UPS a...

Page 7: ...ility power outlet Disconnect the external batteries where applicable and disconnect the internal battery Push the ON button to deenergize the capacitors Jika alat memiliki sumber energi internal batt...

Page 8: ...e package contents The contains of package UPS user manual warranty card input power cable CD software and interface cable Location This UPS Should be located in protected place Lokasi Letakkan UPS in...

Page 9: ...engan menekan tombol daya Led merah pada TARAF BATERAI akan menyala sekitar 5 detik dan padam kembali bila kondisi baterai baik Bersamaan dengan itu led hijau LISTRIK JALA JALA menyala bila teganganny...

Page 10: ...sufficient runtime The unit is being charged whenever it is connected to utility power and UPS must be turn ON Catatan Battery UPS harus di isi sekurangnya 10 jam untuk memastikan UPS beroperasi denga...

Page 11: ...NTPL NTPC Consists of LED L11 L12 L13 L14 L15 L16 Audible alarm sounds every 4 seconds Audible alarm sounds every 1 second Don t care depends or battery conditions Continuos sound Off Yellow led look...

Page 12: ...ating 2 If the fuse blown again call for service 1 Install the interface cable 2 See software manual 3 If the problem still occurred call for service 1 Interface cable not connected 2 Interface cable...

Page 13: ...SERVICE CENTRE ICA Jln Pinangsia Raya I No 22BB Jakarta 11120 Phone 021 6906020 Hunting Unuk informasi servis kota kota lain kunjungi cari menu support www icaups co id...

Reviews: