Buzzer
LED
NTPL NTPC L1
L2
L3
Remarks
Main
Switch
Status
Condition
All normal
Line voltage
abnormal at low
battery voltage
Save your work now, the inverter
will be cut off.
1
1
1
0
0
1
0
1
-
0
0
0
1
0
1
1
0
1
0
-
1. Make sure main switch on the “off” position
and no load is connected to the outlet.
2. Connect inlet with power cord to a power
receptacle with earth ground.
3. Turn on the UPS by pressing power button.
The red led lights for about 2 seconds and
will go out when the battery is in good
condition.
At the same time the green led
light (if line voltage >165V and <250V)
which indicates UPS output is from line
power.
4. Disconnect inlet from line power, the green
led will go out while the yellow led will light
on and audible alarm will sound every 4
seconds.
5. Connect inlet to line power again and then
after about 2 seconds the yellow led will go
out while the green led of line on will light
on.
6. Now your UPS is ready for operation.
Connect the equipment that is going to be
supplied by the UPS into the UPS.
1. Pastikan tombol pada posisi “off” dan tidak
ada beban yang terpasang pada stopkontak
keluaran.
2. Hubungkan steker kabel daya ke stopkontak
jala-jala yang mempunyai arde.
3. Hidupkan UPS dengan menekan tombol daya.
Led merah akan menyala sekitar 2 detik dan
padam kembali bila kondisi baterai baik.
Bersamaan dengan itu led hijau menyala (bila
tegangannya >165V dan <250V) yang
menunjukkan keluaran UPS berasal dari
listrik jala-jala.
4. Cabut steker kabel daya dari stopkontak jala-
jala maka led hijau padam sedangkan led
kuning akan menyala dan buzzer akan
berbunyi setiap 4 detik.
5. Pasang kembali steker maka sekitar 2 detik
kemudian led kuning padam sedangkan led
hijau akan menyala.
6. Sekarang UPS siap menjalankan fungsinya.
Hubungkan peralatan yang akan diberi
pasokan daya pada stopkontak keluaran UPS.
Remark:
L1: Green Led (Line On)
NTPL: Audible alarm sound every 4 seconds
L2: Yellow Led (Inverter)
NTPC: Audible alarm sound every 1 second
L3: Red Led (Battery Low)
VII. START UP UPS /
MENGHIDUPKAN UPS
VIII. TABLE OF STATUS INDICATOR /
TABEL STATUS INDIKATOR
Line voltage
abnormal
1
0
1
0
1
0
Check the line power, make sure
between 165~250 Vac.
Line voltage
normal at low
battery voltage