Parameter
Description
Interval (Sec.)
The NVR will not send emails caused by frequent alarm events of
the same type within the interval time
The value ranges from 0 to 3600. Select 0 disable interval.
Health Mail
The NVR can send a test email to check the connection at the
specified Inteval.
Sending Interval
This is the interval that the system sends a health test email.
The value ranges from 30 to 1440. 0 means that there is no
interval.
Test
Click
Test
to test the email sending function. If the configuration is
correct, the receiver’s email account will receive the email.
Before testing, click
Apply
to save the settings.
Step 3
Click
Apply
to complete the settings.
4.11.7 SNMP
SNAMP allows the NVR to be managed by a database such as a MIB. Once configured, you
can utlize software such as MIB Builder and MG-SOFT MIB Browser to manage and control
the NVR from the software.
Prerequisites
● Install the software that can manage and control the SNMP, such as MIB Builder and
MG-SOFT MIB Browser
● Obtain the MIB files that correspond to the current version from the technical support.
This function is not supported in all NVR models.
Procedure
Step 1
Select
Main Menu
>
Advanced Settings
>
NETWORK
>
SNMP
.
The SNMP interface will be displayed. See Figure 4-230.
Figure 4-230
216