For materials which are not listed, please request information from manufacturer/supplier.  

 

Before using other method for cleaning or decontamination, the user must ascertain with the manufacturer/supplier 
whether this method will not harm the instrument.  

 

Wear the proper protective gloves during cleaning of the instrument. 

 
 

 

Note: 

• Electrical instruments may not be placed in the 

cleansing agent. 

•  The  instrument  is  a  sophisticated  electronic 

product; please avoid severe shaking during use 
and transportation. 

• The instrument must be cleaned and put it into 

the initial packaging  carton before sending for 
service, avoid contamination. 

• Switch OFF the instrument and put it in a dry, 

clean,  stable  place  at  room  temperature  in 
long-term disuse. 

 

7.

 

Associated Standards and Regulations 

 

Construction in accordance with the following safety 
standards: 
EN 61010-1 
Construction in accordance with the following EMC 
standards: 
EN 61326-1 
Associated EU guidelines: 
EMC-guidelines: 2004/108/EC 
Instrument guidelines: 73/023/EWG 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for V05

Page 1: ...V05 Adjustable Speed Vortex Please read the User Manual carefully before use and follow all operating and safety instructions user manual english ...

Page 2: ...Please provide the customer care representative with the following information Serial number Description of problem Your contact information Warranty This instrument is warranted to be free from defects in materials and workmanship under normal use and service for a period of 24 months from the date of invoice The warranty is extended only to the original purchaser It shall not apply to any produc...

Page 3: ...ration is only guaranteed with the accessories described in the Accessories chapter Accessories must be securely attached to the instrument and cannot come off by themselves Check the instrument and accessories before each use Do not use damaged components Place a vessel at the center of the mixing head A sharp edged vessel can wear out the mixing head Always disconnect the plug before fitting acc...

Page 4: ...ng on If these operations above are normal the instrument is ready to operate following the operation chapter If these operations are not normal the instrument may be damaged Please contact manufacturer supplier for technical support 5 Operation Figure 2 A B C D E F A Mixing Head B Continuous mode indicator Low speed area C Touch mode indicator High speed area D Power LED E Speed control knob F Tw...

Page 5: ... head vertically the instrument will begin to work and the power LED will be lit Push the two direction switch left gently to OFF Note Place vessels as vertical as possible into the center of mixing head for proper mixing Adjust the speed control knob slowly in order to have the instrument works smoothly Don not run continuous operating mode at high speed area 6 Maintenance and Cleaning Proper mai...

Page 6: ...rument is a sophisticated electronic product please avoid severe shaking during use and transportation The instrument must be cleaned and put it into the initial packaging carton before sending for service avoid contamination Switch OFF the instrument and put it in a dry clean stable place at room temperature in long term disuse 7 Associated Standards and Regulations Construction in accordance wit...

Page 7: ...Orbital diameter mm 4 Motor type Shaded pole motor Motor rating input W 58 Motor rating output W 10 Speed range rpm 0 2500 Speed display Scale Run type Continuous touch operation Dimensions mm 127 130 160 Weight kg 3 5 Permitted ambient temperature C 5 40 Permitted relative humidity 80 Protection class acc to DIN 60529 IP21 ...

Page 8: ...ORX A06 001 MIXS A51 001 Tube adapter for 18 holes test tubes Ø10mm used with VORX A04 001 VORX A06 001 MIXS A61 001 Tube adapter for 12 holes test tubes Ø12mm used with VORX A04 001 VORX A06 001 MIXS A71 001 Tube adapter for 8 holes test tubes Ø16mm used with VORX A04 001 VORX A06 001 MIXS A81 001 Tube adapter for 8 holes test tubes Ø20mm used with VORX A04 001 VORX A06 001 VORX A05 001 Platform ...

Page 9: ...ed area VORX A03 001 Y Y VORX A06 001 MIXS A41 001 Y VORX A06 001 MIXS A51 001 Y VORX A06 001 MIXS A61 001 Y VORX A06 001 MIXS A71 001 Y VORX A06 001 MIXS A81 001 Y VORX A04 001 VORX A05 001 Y VORX A04 001 MIXS A41 001 Y VORX A04 001 MIXS A51 001 Y VORX A04 001 MIXS A61 001 Y VORX A04 001 MIXS A71 001 Y VORX A04 001 MIXS A81 001 Y ...

Page 10: ...10 ...

Page 11: ...www labbox com ...

Reviews: