Configuration charge setting
When the DBM is in the charging setting, the relay LED lights up
green. Six different charging modes can be set in this
configuration step. If a short ground contact is made with the Link
/ Prog line, the system switches to the next charge level. The 6
selection levels repeat in a cycle.
Charge Select Indication
Low Level
Charge level Low (14.0V)
Medium Level
Charge level Medium (14.4V)
High Level
Charge level High (14.8V)
Equalize
Equalize mode: Low/Mid/High +0.6V (only
temporary)
Notice
Before configuring the Charge Level determine whether Equalize Mode is necessary for the Aux-Battery
and whether any appliances are connect to the Aux Battery, which could shut down due to high Charge
Voltage.