background image

EC DECLARATION OF CONFORMITY (Module A):

PHU Dambat, Gawartowa Wola 38, 05-085 KAMPINOS, POLSKA, e-mail: 

[email protected]

 

Under the Act of 30 August 2002 on the conformity system (Journal of Laws of 2004, No. 204, 
item 2087), we declare, assuming full liability, that the pumps and booster sets with 2L, 24L, 
50L capacity tanks, series:
JET100A(a)TF, AJ 50/60, MH 1300 (INOX), MHI 1300 (SS), MHI 2200 (SS), MHI 2500 (SS), 
JSW 150, WZ250, WZ750, QB60, WZ250 hydr 2L, DP355A, JET100A, SCM32, JSW 200, 
MultiHWA 4000 INOX, MultiAJ 1300 SS, MHI 1100 SS, JSW150INOX, Multi1300INOX, WG, 
WGZ, MH1500, MH1500INOX, WZC250, WZC750, WZCH250, BJ45/75, ATLAS125, 
WZI250,WZI750, HP1500 this declaration refers to, are compliant with the following 
Directives of the European Parliament and Council, as amended:
1) MD 2006/42/WE (applied standards EN 292-1:1991, EN 292-2-1991/A1: 1995, PN- EN 

809:1999/AC: 2004)

2) EMC 2004/108/WE (applied standards PN-EN 55014-1:2004, PN-EN 61000-3-2:2004)
3) LVD 2006/95/WE (applied standards PN-EN 60335-1:2004+A1:2005+A2:2008+ A12: 

2008, PN-EN 60335-2-41:2005)

Under Art. 9 of Directive no. 97/23/EC, the pumps and booster sets with 50L and lower capacity 
tanks are qualified as category I pressure devices.

Adam Jastrzębski 23.11.2008

TECHNICAL DATA

TYPE:

M

ot

o

p

o

w

e

r

C

o

il 

C

u

rr

e

nt

P

o

w

e

r

su

p

p

ly

vo

lta

ge

M

a

x.

e

ffi

ci

e

n

cy

M

a

x.

 h

e

ad

 

he

ig

h

t

M

a

x.

 s

u

ct

io

n

d

ep

th

S

u

ct

io

n

/d

is

cc

h

a

rg

e

p

o

rt

H

ig

h

e

st

a

d

m

is

si

b

le

 b

oo

st

e

se

p

re

ss

u

re

[W]

[A]

[V]

[l/min]

[m]

[m]

P

 

s max 

[bar]

JET100A(a)

1100

2.4

~230

60

50

8

1 ”x 1

4

AJ 50/60

1100

2.4

~230

60

50

8

1 ”x 1

4

MHI1100SS

1100

5.0

~230

32

109

8

1 ”x 1

4

MHI 1300

1300

6.0

~230

100

55

8

1 ”x 1

4

MH 1300 INOX

1300

6.0

~230

100

55

8

1 ”x 1

4

MHI 1300SS

1300

6.0

~230

100

55

8

1 ”x 1

4

MHI 2200 (SS)

2200

10.0

~230

165

61

8

1

¼

”x1

¼

4

MHI 2500 (SS)

2500

11.5

~230

150

105

8

1 ”x 1

4

BJ 45/75

1100

3.9

~230

75

45

7.5

1

¼ 

” x 1”

4

JSW 150

1500

3.7

~230

80

46

8

1 ”x 1

4

JSW150 INOX

1500

3.7

~230

70

45

8

1 ”x 1

4

WZI250

250

1.6

~230

35

35

8

1 ”x 1

4

WZI750

750

3.2

~230

50

60

8

1 ”x 1

4

WZC / WZCH 250

250

1.6

~230

30

30

8

1 ”x 1

4

WZC 750

750

4.6

~230

70

45

8

1 ”x 1

4

JET100A

1100

4.0

~230

60

50

8

1 ”x 1

4

WZ 250 hydr 2L

250

1.6

~230

35

35

7

1 ”x 1

4

ATLAS125

1250

4.35

~230

70

54

8

1 ”x 1

4

JSW 200

1800

7.5

~230

100

63

8

1 ”x 1

4

MultiHWA4000

INOX

1800

7.4

~230

120

53

8

1 ”x 1

4

MH1500 (INOX)

1500

7.5

~230

100

65

8

1 ”x 1

4

HP1500

1500

9.6

~230

110

63

8

1 ”x 1

4

Multi1300 INOX

1300

6.0

~230

70

50

8

1 ”x 1

4

7

Summary of Contents for QB-60

Page 1: ...f the well from which you are going to pump the water is sufficient i e whether the efficiency of the purchased pump is not too high in relation to the well capacity Installation of the pump that is too large can stop the water flow in the suction pipe and result in dry pump operation without water Pumps with capacities of 100 l min and higher require new efficient wells This equipment is not inte...

Page 2: ...al section x 0 15for diameter 1 2 25 m In total the negative pressure is 5_2 25 7 25 m In this example the negative pressure of 8 m is not exceeded and the booster pump should operate without problems If the negative pressure of 8 m is exceeded during operation e g when the water level decreases during pumping the booster pump can be damaged due to operation without water flow This type of failure...

Page 3: ... for the pump or booster set must be 230V 50Hz with earthing The suction pipe must be connected to the pump by means of the suction port using a flexible non collapsible hose hose available for purchase from the guarantor so that the pipe stress is not transferred to the pump NOTE do not use anti vibration hoses in metal plait for connection of the pump and suction pipe This type of hoses can be u...

Page 4: ...nection ELECTRIC INSTALLATION The electric network used to power the device must be compliant with data provided on the rating plate The device plug must be connected to a socket with earthing The manufacturer and guarantor are not liable for any damage to people or property resulting from lack of proper earthing The yellow green core of the connection cable is earthing The powering network must b...

Page 5: ...t once every 3 months during continuous use or at the beginning of the spring summer season if the booster set is used in a recreational plot or when excessively frequent switch on of the pump is found more frequently than usual The air pressure in the tank can be checked when the booster set is unplugged and the tap is open When the water pressure in the installation drops to zero the air pressur...

Page 6: ... repairs QB 60 WZ WZ WZC WZCH WZI type pumps require unclogging after a standstill period without water Clogging results from sticking of the rotor to the housing due to the water sediments resulting from evaporation In order to unclog the pump move the pump shaft before starting the device To facilitate this insert a flat screwdriver in the shaft slit visible in the central part of the fan casing...

Page 7: ...and booster sets with 50L and lower capacity tanks are qualified as category I pressure devices Adam Jastrzębski 23 11 2008 TECHNICAL DATA TYPE Motor power Coil Current Power supply voltage Max efficiency Max head height Max suction depth Suction disccharge port Highest admissible booster set pressure W A V l min m m P s max bar JET100A a 1100 2 4 230 60 50 8 1 x 1 4 AJ 50 60 1100 2 4 230 60 50 8 ...