IBO BETA Instruction Manual Download Page 8

 

POSSIBLE 

OPERATION 

PROBLEMS 

AND 

TROUBLESHOOTING 

Sign: 

Possible cause: 

Problem solution: 

The 

pump 

does 

not 

operate. The panel does not 
display anything.

 

No power supply. Pump damaged

 

Check  if  the  electric plug  of  the pump  is  properly 
inserted into the electric socket.

 

Check  fuses  at  home  and  all  other  types  of 
installation fuses that can cut off the power supply 
from the network

 

Check  if  there  is  a  power  supply  in  your 
neighbourhood  -  power  can  be  shut  down  by  the 
power enterprise in the larger area Contact service.

 

The 

pump 

does 

not 

operate. The panel displays 
the  following  message:  “- 
-”

 

Incorrect parameters of supplying power.

 

Check parameters of supplying power. If they are 
incorrect, contact with the proper power plant

 

Bearing or rotor is blocked with contamination.

 

Upon disconnection of the pump from power and 
water supply, remove the pump from the 
installation. Remove contamination.

 

Loud pump operation, 
noise in the installation 
Panel displays a number

 

Air pockets in installation

 

Deaerate the system, deaerate the pump.

 

Suction pressure is too low

 

Increase suction pressure by adding more heating 
medium to the installation.

 

Check the amount of air in the collecting container.

 

Pump capacity is too high

 

Decrease pressure on the suction side of the device

 

Pump is operating but 
installation fails to supply 
enough heat. Panel 
displays a number

 

Too low pump operation parameters 

 

Increase pressure on the suction side of the device 
Switch the pump setpoint into a higher operation 
mode.

 

EC DECLARATION

 

OF CONFORMITY (Module A):

 

PHU Dambat 
Gawartowa Wola 38, 05-085 KAMPINOS, POLSKA, e-mail: [email protected] Under the Act of 
30 August 2002 on the conformity system (Journal of Laws of 2004, No. 204, item 2087) we 
declare  with  full  responsibility  that  BETA  pumps  to  which  this  declaration  refers  to  are 
consistent  with  the  following  guidelines  of  the  Council  on  legal  regulations  unification  in 
member states of EC: 

 

Low Voltage Directive LVD (2006/95/EC). Applied standard: EN 60335-2- 51:2003. 

 

Directive EMC (2004/108/EC) Applied norms: EN 55014-1:2006 and EN 55014- 2:1997. 

 

Eco-design Directive (2009/125/EC) Circulation pumps: 

Regulation of the Commission (EC) no. 641/2009. Applied norms: EN 16297-1:2012 and EN 
16297-2:2012. 

Gawartowa Wola 23.08.2011 

Adam Jastrzębski 

The reference criterion for most energy saving circulation pumps is EEI < 0.20. 
For BETA pump, the coefficient EEI< 0.23 which means that BETA pump is an energy saving 
pump. 

Summary of Contents for BETA

Page 1: ...arising from potential device failure caused by the use that is inconsistent with instructions of its use NOTE failure to observe the instructions included in the manual can result in hazard for persons properties in which they are installed environment and the pump itself CAUTION This equipment is not intended for use by persons including children with reduced motor sensory or mental capacities o...

Page 2: ...pumping of clean water with no solid or abrasive particles Pumping water containing mechanical contamination results in fast wear and tear of the pump and in consequence it its failure In such a case only paid repair is available The pump is not adjusted to pump caustic flammable destructive or explosive substances e g petrol nitro oil etc foodstuffs or salty water Failure caused by pumping of the...

Page 3: ...bottom This type of installation protects against water penetration into the cable box in case of leakage in the water installation Device destruction caused by pouring water into the terminal box from the outside is not subject to warranty repair Despite the possibility of pump operation in water pumping in a vertical downward direction the manufacturer recommends the installation which makes it ...

Page 4: ...uipped with a residual current device with rated making current In not exceeding 30 mA The manufacturer and guarantor are not liable for any damage to people or property resulting from supplying the pump with power without a proper switch PUMP OPERATION CONTROL Upon launch of the pump the display of the power consumption meter will show the current power consumption of the pump When the message tw...

Page 5: ...rameters of pump operation depending on the selected operation mode are presented in the diagram example diagram for pump BETA 25 60 RECOMMENDED SETPOINTS DEPENDING ON THE TYPE OF CENTRAL HEATING CO INSTALLATION 1 If there is a two pipe central heating installation routed in the house i e one pipe serves as the supply line for all heaters in the loop and the other in parallel position is used only...

Page 6: ...rate with a pump operating in a night mode The principle of NIGHT MODE operation The use of the night mode switch will cause the automatic system of the pump will monitor the temperature changes in flowing water If the temperature signalling unit detects temperature lowering of at least 0 1 O C min in the period of about 2 hours it will result in automatic switch the pump into night operation mode...

Page 7: ...not exceed 70O C For 35O C of surroundings the max temp of medium is 90O C Device destruction as a result of water steam condensation is not subject to warranty repair The temperature of pump surface can never exceed 120O C Device destruction as a result of installation overheating is not subject to warranty repair PUMP DISPOSAL The used product is subject to disposal as wastes only in selective w...

Page 8: ...to the installation Check the amount of air in the collecting container Pump capacity is too high Decrease pressure on the suction side of the device Pump is operating but installation fails to supply enough heat Panel displays a number Too low pump operation parameters Increase pressure on the suction side of the device Switch the pump setpoint into a higher operation mode EC DECLARATION OF CONFO...

Reviews: