Electronic circulator pump operating manual:  

BETA 25-60 

 

CAUTION  Prior  to  operation,  please  read  this  operating 
manual.  Due  to  safety  reasons,  the  use  of  this  equipment 
requires a thorough knowledge of this operating manual.  

 

 CAUTION  This  operating  manual  is  the  primary  basis  for  the 
equipment’s  sale  contract.  Non-observance  of  the  recommendations 

listed  in  this  manual  will  result  in  a  breach  of  this  contract  and  will 
invalidate  any  claims  made  by  the  user  relating  to  the  equipment’s  failure 
resulting from its inappropriate use. 

   

 CAUTION  Non-observance  of  recommendations  listed  in  this 
operating manual may result in personal injuries or damage to 
units  where  the  equipment  is  installed,  the  environment  or  the 

pump itself.   

 
CAUTION!  Children  and  persons  with  reduced  physical, 
sensory  or  mental  capabilities  must  not  use  this  equipment; 
also  persons  with  no  experience  or  knowledge  of  the  product 

unless  under  the  supervision  or  in  accordance  with  the  equipment’s 
operating  manual  and  instructed  by  a  person  responsible  for  their  safety. 
Children must not play with this equipment. 

  

Summary of Contents for BETA 25-60

Page 1: ...s made by the user relating to the equipment s failure resulting from its inappropriate use CAUTION Non observance of recommendations listed in this operating manual may result in personal injuries or damage to units where the equipment is installed the environment or the pump itself CAUTION Children and persons with reduced physical sensory or mental capabilities must not use this equipment also ...

Page 2: ...igned to pump substances which are corrosive flammable or have damaging or explosive properties for example petrol nitro petroleum etc as well as foodstuffs and salt water Equipment failures caused by this type of damage are not covered by the product s warranty The maximum temperature of pumped water is 110o C The pump is not adapted to pump water with an excessive level of mineral particles as t...

Page 3: ... mechanical impurities into the pipework The pipework should be flushed through prior to the installation of the pump The pump should be installed with its shaft in a horizontal position The pump s ports can be in different positions to the ones shown in the picture below however the shaft of the pump must always be in a horizontal position If the pump is installed with its shaft in a vertical pos...

Page 4: ...CAL CONNECTION The pump s power supply network should satisfy the requirements listed on the rating plate The pump has a cable with a plug which can be inserted into an earthed socket The pump needs to be connected to a network with an active earthing system The manufacturer and the guarantor will bear no responsibility for injuries to people or any damage caused by the lack of an appropriate eart...

Page 5: ...d from the electrical network it should be unblocked failure repaired and switched on again Switching it off and then switching it back on again will reset the error message OPERATING MODE The subsequent pressing of the operating mode switch allows the user to select one of the eight settings The selected setting will be displayed by the operating mode display The pump s operating parameters are s...

Page 6: ...second parallel pipe is used to receive the cooled water from the radiators the most economic solution is to select the AUTO function This type of installation also permits the selection of a higher setting from PP1 alternating pressure 2 If a house has a one pipe heating system where the cooled water from a radiator enters a pipe supplying hot water to the next radiator and ...

Page 7: ...riod of approx 2 hours the pump will automatically start operating in night mode If the temperature of the heating medium increases by approx 10O C the pump will automatically return to the standard operating mode The night mode setting will not work if the pump is running in one of its constant speeds Disconnecting the electricity supply will deactivate the night mode Once the power supply is rec...

Page 8: ...he maximum temperature of the heating medium is 110O C With the ambient temperature of 40O C the maximum temperature of the heating medium is 70O C With the ambient temperature of 35O C the maximum temperature of the heating medium is 90O C Any equipment damage caused by water vapour condensation is not covered by a warranty The surface temperature of the pump must not exceed 120O C Any equipment ...

Page 9: ...eating medium to the installation The inlet pressure is too low Check the air quantity in the expansion vessel The pump is noisy there is noise in the installation The panel displays a number The pump performance is too high Decrease the pressure on the suction side The pump is running but provides insufficient heat The panel displays a number The pump operating parameters are too low Increase the...