![IBM xSeries 366 Problem Determination And Service Manual Download Page 80](http://html1.mh-extra.com/html/ibm/xseries-366/xseries-366_problem-determination-and-service-manual_3346977080.webp)
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only)”,
that
step
must
be
performed
only
by
a
trained
service
technician.
Lit
light
path
diagnostics
LED
with
the
system-error
or
system-information
LED
also
lit
Description
Action
CPU
A
microprocessor
has
failed,
is
missing,
or
has
been
improperly
installed.
Note:
Make
sure
that
the
microprocessors
are
installed
in
the
correct
sequence;
see
1.
Check
the
BMC
log
or
the
system-error
log
to
determine
the
reason
for
the
lit
LED.
2.
Find
the
failing,
missing,
or
mismatched
microprocessor
by
checking
the
LEDs
on
the
microprocessor
tray.
3.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
Failing
microprocessor
b.
Microprocessor
tray
4.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
(Trained
service
technician
only)
Failing
microprocessor
b.
(Trained
service
technician
only)
Microprocessor
tray
VRM
A
dc-dc
regulator
has
failed
or
is
missing.
1.
Check
the
BMC
log
or
the
system-error
log
to
determine
the
reason
for
the
lit
LED
(for
a
VRM).
2.
Find
the
failing
or
missing
VRM
by
checking
the
LEDs
on
the
microprocessor
tray.
3.
Install
any
missing
VRMs.
4.
Reseat
the
following
components:
a.
Failing
VRM
b.
(Trained
service
technician
only)
Microprocessor
associated
with
the
VRM
c.
Microprocessor
tray
5.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
Failing
VRM
b.
(Trained
service
technician
only)
Microprocessor
associated
with
the
VRM
c.
(Trained
service
technician
only)
Microprocessor
tray
LOG
Information
is
present
in
the
BMC
log
and
system-error
log.
One
or
both
logs
may
be
full
or
close
to
full.
1.
The
system-error
log
is
75%
full;
save
the
log
if
necessary
and
clear
it
(see
Error
Logs
at
2.
Check
the
log
for
possible
errors
(see
64
IBM
xSeries
366
Type
8863:
Problem
Determination
and
Service
Guide
Summary of Contents for xSeries 366
Page 1: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 8: ...vi IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 28: ...12 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 160: ...144 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 170: ...154 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 181: ...V video connector 6 VRM LED 64 W Web site 1 weight 3 World Wide Web 1 Index 165...
Page 182: ...166 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 183: ......