Symptom
Action
The
power-on
button
does
not
work,
and
the
reset
button
does
work
(the
server
does
not
turn
on).
Note:
The
power
button
will
not
function
until
20
seconds
after
ac
power
has
been
applied
to
the
server.
1.
Make
sure
that
the
operator
information
panel
power-control
button
is
working
correctly:
a.
Disconnect
the
server
power
cords.
b.
Reconnect
the
power
cords.
c.
(Trained
service
technician
only)
Reseat
the
operator
information
panel
cables,
and
then
repeat
steps
and
v
(Trained
service
technician
only)
If
the
server
turns
on,
reseat
the
operator
information
panel.
If
the
problem
persists,
replace
the
operator
information
panel.
v
If
the
server
does
not
turn
on,
bypass
the
operator
information
panel
power-control
button
by
using
the
force
power-on
jumper
(see
if
the
server
turns
on,
reseat
the
operator
information
panel.
If
the
problem
persists,
replace
the
operator
information
panel.
2.
Make
sure
that
the
reset
button
is
working
correctly:
a.
Disconnect
the
server
power
cords.
b.
Reconnect
the
power
cords.
c.
(Trained
service
technician
only)
Reseat
the
light
path
panel
cable,
and
then
repeat
steps
and
v
(Trained
service
technician
only)
If
the
server
turns
on,
replace
the
light
path
panel.
v
If
the
server
does
not
turn
on,
go
to
step
3.
Make
sure
that:
v
The
power
cords
are
correctly
connected
to
the
server
and
to
a
working
electrical
outlet.
v
The
type
of
memory
that
is
installed
is
correct.
v
The
memory
card
is
fully
seated.
v
The
LEDs
on
the
power
supply
do
not
indicate
a
problem.
v
The
microprocessors
are
installed
in
the
correct
sequence.
4.
Reseat
the
following
components:
a.
Memory
card
b.
(Trained
service
technician
only)
Power
switch
connector
c.
(Trained
service
technician
only)
Power
backplane
d.
I/O
board
5.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
6.
If
you
just
installed
an
optional
device,
remove
it,
and
restart
the
server.
If
the
server
now
turns
on,
you
might
have
installed
more
devices
than
the
power
supply
supports.
7.
See
8.
See
Chapter
2.
Diagnostics
57
Summary of Contents for xSeries 366
Page 1: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 8: ...vi IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 28: ...12 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 160: ...144 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 170: ...154 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...