3.
Locate
the
boot
recovery
jumper
(J14
on
the
I/O
board)
(see
4.
Disconnect
the
server
from
the
ac
power
source.
5.
Move
the
J14
jumper
to
pins
2
and
3
to
enable
the
backup
page.
6.
Wait
30
seconds;
then,
connect
the
server
to
the
ac
power
source.
7.
Insert
the
BIOS
flash
diskette
into
the
diskette
drive.
8.
Restart
the
server.
9.
When
POST
starts,
select
1
-
Update
POST/BIOS
from
the
menu
that
contains
various
flash
(update)
options.
10.
When
you
are
asked
whether
you
want
to
save
the
current
code
to
a
diskette,
type
N.
11.
Type
1
and
press
Enter
to
continue.
Attention:
Do
not
restart
or
turn
off
the
server
until
the
update
is
completed.
12.
When
the
update
is
completed,
turn
off
the
server.
13.
Disconnect
the
server
from
the
ac
power
source.
14.
Move
the
J14
jumper
back
to
pins
1
and
2
to
return
to
startup
from
the
primary
page.
15.
Wait
30
seconds;
then,
connect
the
server
to
the
ac
power
source.
16.
Replace
the
cover;
then,
restart
the
server.
System-error
log
messages
A
system-error
log
is
generated
only
if
a
Remote
Supervisor
Adapter
II
SlimLine
is
installed.
The
system-error
log
can
contain
messages
of
three
types:
Information
Information
messages
do
not
require
action;
they
record
significant
system-level
events,
such
as
when
the
server
is
started.
Warning
Warning
messages
do
not
require
immediate
action;
they
indicate
possible
problems,
such
as
when
the
recommended
maximum
ambient
temperature
is
exceeded.
Error
Error
messages
might
require
action;
they
indicate
system
errors,
such
as
when
a
fan
is
not
detected.
Each
message
contains
date
and
time
information,
and
it
indicates
the
source
of
the
message
(POST/BIOS
or
the
service
processor).
Note:
The
BMC
log,
which
you
can
view
through
the
Configuration/Setup
Utility
program,
also
contains
many
information,
error,
and
warning
messages.
In
the
following
example,
the
system-error
log
message
indicates
that
the
server
was
turned
on
at
the
recorded
time.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Date/Time:
2002/05/07
15:52:03
DMI
Type:
Source:
SERVPROC
Error
Code:
System
Complex
Powered
Up
Error
Code:
Error
Data:
Error
Data:
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
90
IBM
System
x3800
Type
8865:
Problem
Determination
and
Service
Guide
Summary of Contents for x3800 - System - 8865
Page 1: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 28: ...12 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 122: ...106 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 130: ...114 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 182: ...166 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 195: ......
Page 196: ...Part Number 31R1860 Printed in USA 1P P N 31R1860...