Error
code
Description
Action
180-xxx-008
Failed
I/O
board
LED
test.
1.
Reseat
the
I/O
board.
2.
Replace
the
I/O
board.
180-xxx-009
Failed
Active
™
PCI
LED
test.
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
PCI-X
switch
card
assembly
b.
I/O
board
2.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
201-198-000
Memory
Test
Aborted:
Could
not
run
the
test;
suspect
microprocessor
tray
error.
1.
Restart
the
server.
2.
Run
the
diagnostic
test
again.
3.
Reinstall
the
diagnostic
programs
(see
4.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
201-198-00n
Memory
Test
Aborted:
Could
not
run
the
test.
Note:
n
=
1-9
(programming
error).
1.
Restart
the
server.
2.
Run
the
diagnostic
test
again.
3.
Reinstall
the
diagnostic
programs
(see
201-xxx-CBN
Failed
Memory
Test:
See
v
C
=
memory
card
[1-4]
v
B
=
physical
bank
[1-2]
Note:
Bank
1
=
DIMMs
1
and
3;
Bank
2
=
DIMMs
2
and
4
v
N
=
failing
DIMM
[1-4]
1.
Reseat
the
following
components:
a.
DIMM
N
b.
Memory
card
C
2.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
Note:
N
=
9
indicates
both
DIMMs
in
physical
bank
B
and
memory
card
C.
202-xxx-0nn
Failed
system
cache
test,
where
nn=APIC
ID.
APIC
ID
Microprocessor
00,
01
1
06,
07
2
10,
11
3
16,
17
4
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
Microprocessor
nn
b.
Microprocessor
tray
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
(Trained
service
technician
only)
Microprocessor
nn
b.
(Trained
service
technician
only)
Microprocessor
tray
86
IBM
System
x3800
Type
8865:
Problem
Determination
and
Service
Guide
Summary of Contents for x3800 - System - 8865
Page 1: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 28: ...12 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 122: ...106 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 130: ...114 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 182: ...166 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 195: ......
Page 196: ...Part Number 31R1860 Printed in USA 1P P N 31R1860...