
server
while
it
is
turned
on
and
you
are
then
unable
to
turn
off
the
server,
see
“Power
problems”
in
the
Problem
Determination
and
Service
Guide
on
the
IBM
Documentation
CD.
Installing
and
using
the
baseboard
management
controller
utility
programs
The
baseboard
management
controller
provides
environmental
monitoring
for
the
server.
If
environmental
conditions
exceed
thresholds
or
if
system
components
fail,
the
baseboard
management
controller
lights
LEDs
to
help
you
diagnose
the
problem
and
also
records
the
error
in
the
BMC
system
event
log.
The
baseboard
management
controller
also
provides
the
following
remote
server
management
capabilities
through
the
OSA
SMBridge
management
utility
program:
v
Command-line
interface
(IPMI
Shell)
The
command-line
interface
provides
direct
access
to
server
management
functions
through
the
IPMI
2.0
protocol.
Use
the
command-line
interface
to
issue
commands
to
control
the
server
power,
view
system
information,
and
identify
the
server.
You
can
also
save
one
or
more
commands
as
a
text
file
and
run
the
file
as
a
script.
v
Serial
over
LAN
Establish
a
Serial
over
LAN
(SOL)
connection
to
manage
servers
from
a
remote
location.
You
can
remotely
view
and
change
the
BIOS
settings,
restart
the
server,
identify
the
server,
and
perform
other
management
functions.
Any
standard
Telnet
client
application
can
access
the
SOL
connection.
For
more
information
about
IPMI
2.0,
see
the
Intelligent
Platform
Management
Interface
Specification
(IPMI
Specification)
,
version
2.0,
available
at
http://www.intel.com.
Enabling
and
configuring
SOL
using
the
OSA
SMBridge
management
utility
program
To
enable
and
configure
the
server
for
SOL
by
using
the
OSA
SMBridge
management
utility
program,
you
must
update
and
configure
the
BIOS
code
and
enable
the
operating
system
for
an
SOL
connection.
Updating
and
configuring
the
BIOS
To
update
and
configure
the
BIOS
code
to
enable
SOL,
complete
the
following
steps.
1.
Update
the
BIOS
code:
a.
Download
the
latest
version
of
the
BIOS
code
from
http://www.ibm.com/
support/.
b.
Update
the
BIOS
code,
following
the
instructions
that
come
with
the
update
file
that
you
downloaded.
2.
Configure
the
BIOS
settings:
a.
Restart
the
server
and
press
F1
when
prompted
to
start
the
Configuration/Setup
Utility
program.
b.
Select
Devices
and
I/O
Ports
;
then,
make
sure
that
the
values
are
set
as
follows:
v
Serial
Port
A
:
Auto-configure
v
Serial
Port
B
:
Auto-configure
Chapter
3.
Configuring
the
server
65
Summary of Contents for x3800 - System - 8865
Page 1: ...IBM System x3800 Type 8865 User s Guide...
Page 2: ......
Page 3: ...IBM System x3800 Type 8865 User s Guide...
Page 26: ...14 IBM System x3800 Type 8865 User s Guide...
Page 92: ...80 IBM System x3800 Type 8865 User s Guide...
Page 94: ...82 IBM System x3800 Type 8865 User s Guide...
Page 102: ...90 IBM System x3800 Type 8865 User s Guide...
Page 103: ......
Page 104: ...Part Number 31R1857 Printed in USA 1P P N 31R1857...