IBM V.90 PCI Replacement Instructions Manual Download Page 4

Table 1. Power supply LED combinations for detecting potential problems (continued)

AC

DC

Error

Description

Action

Notes

Off

Off

On

No AC power is going to
the appliance, or there is a
problem with the AC
power source and the
power supply detected an
internal problem.

1.

Replace the power
supply.

2.

Make sure that the
power cord is
connected to a
functioning power
source.

This condition occurs when
a second power supply is
providing power to the
appliance.

Off

On

Off

The power supply is faulty. Replace the power supply. N/A

Off

On

On

The power supply is faulty. Replace the power supply. N/A

On

Off

Off

The power supply is not
fully seated.

1.

Reseat the power
supply.

2.

If a power channel
error LED on the
system board is not
illuminated, replace
the power supply.

This condition usually
indicates that a power
supply is not fully seated.

On

Off or
flashing

On

The power supply is faulty. Replace the power supply. N/A

On

On

Off

The power supply is
operating normally.

N/A

N/A

On

On

On

The power supply is faulty
but it is still operational.

Replace the power supply. N/A

4

Summary of Contents for V.90 PCI

Page 1: ...tems Safety Notices provided in the IBM Media Terms and Conditions CD that is included with your appliance model Note The illustrations in this document might differ slightly from your appliance model Supported appliances The following table lists the appliance models that are supported by the instructions in this document Product Model IBM Part Number IBM Security Access Manager AMP 5100 97Y0608 ...

Page 2: ...t from the device ensure that all power cords are disconnected from the power source CAUTION Never remove the cover on a power supply or any part that has the following label attached Hazardous voltage current and energy levels are present inside any component that has this label attached There are no serviceable parts inside these components If you suspect a problem with one of these parts contac...

Page 3: ...ect the detected problems Table 1 Power supply LED combinations for detecting potential problems AC DC Error Description Action Notes Off Off Off No AC power is going to the appliance or there is a problem with the AC power source 1 Check the AC power that is going to the appliance 2 Make sure that the power cord is connected to a functioning power source 3 Turn off the appliance and then turn the...

Page 4: ... power to the appliance Off On Off The power supply is faulty Replace the power supply N A Off On On The power supply is faulty Replace the power supply N A On Off Off The power supply is not fully seated 1 Reseat the power supply 2 If a power channel error LED on the system board is not illuminated replace the power supply This condition usually indicates that a power supply is not fully seated O...

Page 5: ...ower supply from the bay as shown in Figure 2 Important During normal operation each power supply bay must contain either a power supply or a power supply blank for proper cooling 2 Slide the AC power supply into the bay until the retention latch clicks into place Make sure that the power supply connects firmly to the power supply connector 3 Connect the power cord for the new AC power supply to t...

Page 6: ...lectrical outlet What to do next Make sure that the AC power LED and the DC power LED on the AC power supply are illuminated which indicates that the power supply is operating correctly The two power LEDs are to the left of the power cord connector Figure 3 Identifying the power cord connectors First edition August 2013 Copyright IBM Corporation 2013 2015 US Government Users Restricted Rights Use ...

Reviews: